Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Monobloc system
Technical data
Monobloc system
Series
Aquarea LT
Aquarea LT
Aquarea T-CAP
Aquarea HT
Phases
single phase
three phase
single phase
three phase
single phase
three phase
Monobloc unit
Model
WH-MDC05F3E5*
WH-MDF06E3E5*
WH-MDF09E3E5*
WH-MDF09C3E5
WH-MDC09C3E5
WH-MDF12C6E5
WH-MDC12C6E5
WH-MDF14C6E5
WH-MDC14C6E5
WH-MDF16C6E5
WH-MDC16C6E5
WH-MDF09C3E8
WH-MDC09C3E8
WH-MDF12C9E8
WH-MDC12C9E8
WH-MDF14C9E8
WH-MDC14C9E8
WH-MDF16C9E8
WH-MDC16C9E8
WH-MXF09D3E5
WH-MXC09D3E5
WH-MXF12D6E5
WH-MXC12D6E5
WH-MXF09D3E8
WH-MXC09D3E8
WH-MXF12D9E8
WH-MXC12D9E8
WH-MHF09D3E5
WH-MHF12D6E5
WH-MHF09D3E8
WH-MHF12D9E8
Output capacity
Heating capacity A-15 / W35
kW
4 .87
5 .93 7 .57
8 .11
8 .74
9 .66
9 .67
7 .99
8 .93
9 .77
10 .14
9 .23
12 .06
9 .0
12 .0
9 .0
12 .0
9 .0
12 .0
Power consumption A-15 / W35
kW
1 .98
2 .53 3 .6
3 .29
3 .78
4 .23
4 .38
3 .17
3 .56
3 .93
4 .24
3 .73
5 .24
3 .54
5 .0
3 .75
5 .57
3 .75
5 .58
Coefficient of performance A-15 / W35
–
2 .46
2 .34 2 .1
2 .47
2 .31
2 .28
2 .21
2 .52
2 .51
2 .48
2 .39
2 .5
2 .32
2 .54
2 .4
2 .4
2 .15
2 .4
2 .15
Heating capacity A-7 / W35
kW
5 .08
5 .6 7 .93
9 .05
11 .02
11 .87
11 .63
9 .13
11 .06
11 .8
11 .35
9 .03
11 .63
9 .0
12 .0
9 .0
12 .0
9 .0
12 .0
Power consumption A-7 / W35
kW
1 .50
1 .99 3 .49
3 .17
3 .9
4 .34
4 .37
3 .04
3 .65
4 .04
4 .11
3 .15
4 .51
3 .2
4 .44
3 .33
4 .8
3 .33
4 .8
Coefficient of performance A-7 / W35
–
3 .38
2 .8 2 .27
2 .85
2 .82
2 .74
2 .66
3 .01
3 .03
2 .92
2 .67
2 .91
2 .6
2 .81
2 .7
2 .7
2 .5
2 .7
2 .5
Heating capacity A2 / W35
kW
4 .75 / 3 .31
2
5 .23 7 .51
8 .85
11 .88
12 .66
12 .83
9 .01
11 .92
12 .68
12 .65
9 .22
11 .76
9
12
9
12
9
12
Power consumption A2 / W35
kW
1 .23 / 0 .81
2
1 .48 2 .38
2 .47
3 .45
3 .90
3 .96
2 .40
3 .33
3 .65
3 .78
2 .52
3 .54
2 .55
3 .53
2 .65
3 .61
2 .65
3 .61
Coefficient of performance A2 / W35
–
3 .88 / 4 .07
2
3 .54 3 .15
3 .58
3 .44
3 .25
3 .24
3 .75
3 .58
3 .47
3 .35
3 .66
3 .32
3 .53
3 .4
3 .4
3 .32
3 .4
3 .32
Heating capacity A7 / W35
kW
4 .91
6 .37 9 .05
8 .9
11 .8
13 .83
15 .79
9 .16
12 .17
14 .13
15 .78
9 .33
12 .08
9
12
9 .0
12 .0
9 .0
12
Power consumption A7 / W35
kW
0 .95
1 .33 2 .11
1 .81
2 .68
3 .27
3 .81
1 .82
2 .6
3 .15
3 .73
1 .96
2 .6
1 .9
2 .57
1 .98
2 .73
1 .98
2 .73
Coefficient of performance A7 / W35
–
5 .17
4 .8 4 .29
4 .91
4 .4
4 .23
4 .14
5 .03
4 .68
4 .49
4 .23
4 .89
4 .73
4 .74
4 .67
4 .55
4 .4
4 .55
4 .4
Heating capacity A2 / W55
kW
3 .40
5 .0
7 .0
8 .8
9 .1
9 .5
9 .8
8 .8
9 .1
9 .5
9 .8
9 .0
12 .0
9 .0
12 .0
9 .0
10 .8
9 .0
10 .8
Power consumption A2 / W55
kW
1 .64
2 .5 3 .88
3 .98
4 .18
4 .4
4 .55
3 .98
4 .18
4 .4
4 .55
4 .11
5 .51
4 .11
5 .51
3 .92
4 .9
3 .91
4 .91
Coefficient of performance A2 / W55
–
2 .07
2 .0
1 .8
2 .21
2 .18
2 .16
2 .15
2 .21
2 .18
2 .16
2 .15
2 .19
2 .18
2 .19
2 .18
2 .3
2 .2
2 .3
2 .2
Cooling capacity A35 / W7
kW
4 .50
–
–
6 .97
–
10 .0
–
11 .5
–
11 .93
–
7 .2
–
10 .0
–
11 .5
–
12 .4
–
7 .0
–
10 .0
–
7 .0
–
10 .0
–
–
–
–
Power consumption A35 / W7
kW
1 .35
–
–
2 .25
–
3 .6
–
4 .4
–
4 .8
–
2 .25
–
3 .6
–
4 .4
–
4 .8
–
2 .25
–
3 .6
–
2 .25
–
3 .6
–
–
–
–
Coefficient of performance (EER) A35 / W7
–
3 .33
–
–
3 .15
–
2 .78
–
2 .61
–
2 .51
–
3 .33
–
2 .78
–
2 .61
–
2 .67
–
3 .11
–
2 .78
–
3 .11
–
2 .78
–
–
–
–
Acoustics
Sound pressure level
1
dB(A)
47
47
49
49
50
51
53
49
50
51
53
49
50
49
50
49
50
49
50
Sound power level
dB(A)
A7/W35: 62
3
A7/W45: 62
3
A7/W55: 62
3
65
67
60
63
63
64
60
62
64
65
60
60
66
67
66
67
66
67
Fan speed, top (heating / cooling)
U / min
580 / 700
580 640
490 / 540
510 / 600
540 / 630
580 / 630
490 / 540
510 / 600
540 / 630
580 / 630
490 / 540
510 / 600
490 / 540
510 / 600
490
520
490
520
Fan speed, bottom (heating / cooling)
U / min
530 / 580
550 / 640
580 / 670
620 / 670
530 / 580
550 / 640
580 / 670
620 / 670
530 / 580
550 / 640
530 / 580
550 / 640
530
560
530
560
Air flow rate (heating / cooling)
m³ / min
43 .3 / 47 .1
46 .7 51 .6 76 .8 / 89 .5
80 / 93 .3
84 / 97 .8
90 / 97 .8
76 .8 / 89 .5
80 / 93 .3
84 / 97 .8
90 / 97 .8
76 .8 / 89 .5
80 / 93 .3
76 .8 / 89 .5
80 / 93 .3
76 .8
80
76 .8
80
Unit data
Dimensions (H × W × D)
mm
865 × 1.283 × 320
1.410 × 1.283 × 320
1.410 × 1.283 × 320
Weight
kg
107
112
153
157
155
158
n . v .
n . v .
Water-side connection
inch AG
R 1 ¼
R 1 ¼
Pump – speed stepping
7
3
3
Pump – power consumption (max.)
W
47
75
190
190
Volumetric flow rate of heating circuit for
A7 / W35 / 30
l / min
14 .3
17 .2 25 .8
25 .8
34 .4
40 .1
45 .9
25 .8
34 .4
40 .1
45 .9
25 .8
34 .4
25 .8
34 .4
25 .8
34 .4
25 .8
34 .4
Minimum circulation
l / min
10
19
10
19
10
19
10
19
10
19
10
19
Safety valve (open / closed)
bar
3 / ≤ 1.86
3 / ≤ 2.65
1.9 / ≤ 1.83
3.0 / ≤ 2.65
Electric
Capacity of the additional electric heater
kW
3
6
3
9
3
6
3
9
3
6
3
6
Power consumption (heating / cooling)
kW
0 .99 / 1 .35
1 .36 2 .2
1 .9 / 2 .25
2 .57 / 3 .6
3 .11 / 4 .4
3 .78 / 4 .8
1 .9 / 2 .25
2 .57 / 3 .6
3 .11 / 4 .4
3 .78 / 4 .8
1 .9
2 .57
1 .9
2 .57
1 .98
2 .73
1 .98
2 .73
Operation and starting current (heating / cooling) A
6 .1
6 .2 10 .1
8 .7 / 10 .2
11 .6 / 16 .1 14 .1 / 19 .7 17 .1 / 21 .5
2 .9 / 3 .4
3 .9 / 5 .3
4 .7 / 6 .6
5 .7 / 7 .2
8 .8 10 .4 11 .9 16 .7
2 .9
3 .9
9 .5
13
9 .5
12 .8
Power supply 1 (current consumption)
A
19 .5
20 .5 22 .9
22 .9
24
25
26
11 .8
8 .8
9 .4
9 .9
25
29
14 .7
11 .9
28 .5
29
32 .8
29
Power supply 1 (frequency / voltage)
Hz / V
50 / 230
50 / 400
50 / 230
50 / 400
50 / 230
50 / 400
Power supply 2 (current consumption)
A
13
26
13
26
13
26
13
Power supply 2 (frequency / voltage)
Hz / V
50 / 230
50 / 230
50 / 230
50 / 230
50 / 230
50 / 230
Power supply 3 (current consumption)
A
–
–
–
–
13
13
13
–
13
13
13
–
13
–
13
–
13
–
13
Power supply 3 (frequency / voltage)
Hz / V
–
–
–
50 / 230
–
50 / 400
–
50 / 230
–
50 / 400
–
50 / 230
–
50 / 400
Temp.-
ranges
Operating range (outside temperature)
°C
-20 to 35 / 16 to 43
-20 to 35
-20 to 35
-20 to 35
Operating range (supply water temp. (H / C)
°C
25 to 55 / 5 to 20
22 to 55 / 5 to 20
25 to 65
25 to 65
Panasonic measurement data in accordance with EN 14511-2. The data is to be considered as guidance values and not as a performance guarantee
* Devices have a high efficiency pump and fulfil the criteria of the Ecodesign Directive valid from 2015 for energy-related products (ErP)
1
Measured value in 1 m distance and in 1.5 m height
2
According to EHPA test regulation > 60 %
3
Measured as per BS EN 12102
Technical data of the monobloc units