126
Aquarea air / water heat pump – design handbook 07 / 2014
Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea T-CAP
Outside temperature
Supply water temperature
Models
30
35
40
45
50
55
9 kW (single phase)
WH-MXF09D3E5
WH-MXC09D3E5
-15
9 .0
9 .2
9 .0
9 .0
9 .0
9 .0
-7
9 .0
9 .0
9 .0
9 .0
9 .0
9 .6
2
9 .0
9 .2
9 .0
9 .0
9 .0
9 .0
7
9 .0
9 .3
9 .0
9 .2
9 .0
9 .1
25
13 .6
13 .6
13 .2
12 .8
12 .0
11 .2
30
35
40
45
50
55
12 kW (single phase)
WH-MXF12D6E5
WH-MXC12D6E5
-15
12 .0
12 .1
11 .5
11 .0
10 .7
10 .5
-7
12 .0
11 .6
12 .0
12 .0
12 .0
9 .0
2
12 .0
11 .8
12 .0
12 .0
12 .0
12 .0
7
12 .0
12 .1
12 .0
12 .5
12 .0
12 .7
25
13 .6
13 .6
13 .4
13 .2
12 .6
12 .0
30
35
40
45
50
55
9 kW (three phase)
WH-MXF09D3E8
WH-MXC09D3E8
-15
9 .0
9 .0
9 .0
9 .0
9 .0
9 .0
-7
9 .0
9 .0
9 .0
9 .0
9 .0
9 .0
2
9 .0
9 .0
9 .0
9 .0
9 .0
9 .0
7
9 .0
9 .0
9 .0
9 .0
9 .0
9 .0
25
13 .6
13 .6
13 .2
12 .8
12 .0
11 .2
30
35
40
45
50
55
12 kW (three phase)
WH-MXF12D9E8
WH-MXC12D9E8
-15
12 .0
12 .0
11 .5
11 .0
10 .7
10 .5
-7
12 .0
12 .0
12 .0
12 .0
12 .0
12 .0
2
12 .0
12 .0
12 .0
12 .0
12 .0
12 .0
7
12 .0
12 .0
12 .0
12 .0
12 .0
12 .0
25
13 .6
13 .6
13 .4
13 .2
12 .6
12 .0
Heating capacity [kW] of individual models of the
monobloc system
for different supply water and outside temperatures [°C].