33
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Bi-Bloc system
Technical data
Bi-Bloc system
Series
Aquarea LT
Aquarea LT
Aquarea T-CAP
Aquarea HT
Phases
single phase
three phase
single phase
three phase
single phase three phase
Outdoor unit
Model
WH-UD03EE5
WH-UD05EE5
WH-UD07FE5
2
WH-UD09FE5
2
WH-UD12FE5
2
WH-UD14FE5
2
WH-UD16FE5
2
WH-UD09FE8
2
WH-UD12FE8
2
WH-UD14FE8
2
WH-UD16FE8
2
WH-UX09FE5
2
WH-UX12FE5
2
WH-UX09FE8
WH-UX12FE8
WH-UX16FE8
WH-UH09FE5
2
WH-UH12FE5
2
WH-UH09FE8
2
WH-UH12FE8
2
Acoustics
Sound pressure level
1
dB(A)
47
48
48
50
50
52
54
49
50
52
54
49
50
49
50
54
49 50
49
50
Sound power level
dB
65
66
66
68
68
70
72
66
67
70
72
66
68
A7/W35: 61
3
A7/W55: 66
3
A7/W35: 63
3
A7/W55: 67
3
A7/W35: 63
3
A7/W45: 65
3
A7/W55: 69
3
66
67
66
67
Fan speed, top (heating / cooling)
U / min
800 / 950 860 / 980 580 / 670 640 / 700 510 / 600 540 / 630 580 / 630
490 / 550 510 / 600 540 / 630 580 / 630 490 / 550 520 / 600
490 / 530
520 / 600
500 / 680
490 520 490 520
Fan speed, bottom (heating / cooling) U / min
–
–
–
–
550 / 640 580 / 670 620 / 670
530 / 590 550 / 640 580 / 670 620 / 670 530 / 590 560 / 640
550 / 590
560 / 640
540 / 720
530 560 530 560
Air flow rate (heating / cooling)
m³ / min
31 .9 / 38 .1 34 .4 / 39 .3 46 / 56 .3 51 / 56 .3 80 / 93 .3 84 / 97 .8 90 / 97 .8
76 .8 / 89 .5 80 / 93 .3 84 / 97 .8 90 / 97 .8 76 .8 / 89 .5 80 / 93 .3 76 .8 / 89 .5
80 / 93 .3
76 / 109 .4
76 .8 80 76 .8 80
Unit data
Dimensions (H × W × D)
mm
622 × 824 × 298
795 × 900 × 320
1,340 × 900 × 320
1,340 × 900 × 320
Weight
kg
39
66
101
108
107
109
119
104
102
Pipe diameter (liquid)
mm (Zoll)
6.35 (1/4")
9.52 (3/8")
9.52 (3/8")
9.52 (30/8'') 9.52 (30/8'')
Pipe diameter (gas)
mm (Zoll)
12.70 (1/2'')
15.88 (5/8")
15.88 (5/8")
15.88 (5/8'') 15.88 (5/8'')
Refrigerant
kg
1.2 (R410A)
1.45 (R410A)
2.55 (R410A)
2.55 (R410A)
3.1 (R410A)
2.85 (R410A)
2.9 (R410A)
2.9 (R407C)
Pipe length
m
3 to 15
3 to 30
3 to 30
Nominal pipe length
m
7
7
Pre-filled pipe length
m
10
10
Additional refrigerant filling
g / m
20
30
50
50
70
Max. height difference IG / AG
m
5
20
20
Temperature
ranges
Operating range
(outside temperature)
°C
-20 to 35
-20 to 35
Operating range
(supply water temp. (H / C)
°C
25 to 55 / 5 to 20
25 to 55 / 5 to 20
25 to 65
1
Measured value in 1 m distance and in 1.5 m height
1
Measured value in 1 m distance and in 1.5 m height
2
Preliminary data
2
Preliminary data
3
Measured as per BS EN 12102
3
Measured as per BS EN 12102
Technical data of the Bi-Bloc system units