Item
Setting details
IP ADDRESS PORT
Sets the port of the unit.
Values from 35200 to 35599 can be set.
(Factory default: 35200)
IP ADDRESS UPLOAD
When you press the menu operation dial, the unit's IP address and port will be set.
SUBNET MASK 1
Sets the subnet mask of the unit.
The follow values can be set.
(Factory default: 255.255.255.0)
1st octet: 128, 192, 224, 240, 248, 252, 254, 255
2nd octet: 0, 128, 192, 224, 240, 248, 252, 254, 255
3rd octet: 0, 128, 192, 224, 240, 248, 252, 254, 255
4th octet: 0, 128, 192, 224, 240, 248, 252, 254, 255
SUBNET MASK 2
SUBNET MASK 3
SUBNET MASK 4
SUBNET MASK UPLOAD
When you press the menu operation dial, the unit's subnet mask will be set.
DEFAULT GATEWAY
Sets the default gateway of the unit.
The setting ranges are as follows.
(Factory default: 192.168.0.1)
1st octet: 1 to 223
2nd octet: 0 to 255
3rd octet: 0 to 255
4th octet: 1 to 254
However, the following addresses cannot be set.
Check the setting values during configuration.
0.*.*.*, *.*.*.0, *.*.*.255, 127.0.0.1
Class D address (224.0.0.0 to 239.255.255.255)
Class E address (240.0.0.0 to 255.255.255.255)
DEFAULT GATEWAY UPLOAD
When you press the menu operation dial, the unit's default gateway will be set.
MAC ADDRESS
Display the unit 's MAC address. (Display only)
NOTE
Performing [UPLOAD] after changing the settings will store the setting value changes to the internal memory. Perform [UPLOAD]
on each screen. The setting values stored to memory will be applied after the unit is restarted.
- 114 -