Master pedestal (M.PED)
Displaying and setting the master pedestal (M.PED)
The master pedestal (M.PED) setting value appears in the adjustment value display (A) when the master pedestal dial (B) is operated.
Adjustment is possible when [IRIS] is selected under [ROP SETTING] > [M.PED CONT] in the ROP menu.
“M.PED CONT” (see page 110)
B
A
A. Adjustment value display
B. Master pedestal dial
Operating procedure
1. Turn the master pedestal dial (B).
Change the master pedestal value.
The master pedestal and the R, G, and B pedestal can be adjusted independently.Changing the master pedestal set-
ting does not change the R, G, and B pedestal settings values.