36 (E)
ENGLISH
1 2
GND
IN
REC IN
GND TIME ADJ IN
TAPE END OUT
RESET
ALARM
EXT
TIMER
OUT
IN OUT
WARNING
/REC OUT
Terminal connections
Tape-end output connections
When the cassette tape comes to its end during
recording, the alarm device which has been installed
externally is triggered.
Alarm lamp
External
interface
1 2
GND
IN
REC IN
GND TIME ADJ IN
TAPE END OUT
RESET
ALARM
EXT
TIMER
OUT
IN OUT
WARNING
/REC OUT
External timer input connections
An external timer can be used for recording.
O
Select ON for EXT TIMER IN on the menu screen
shown on P7 TERMINAL INPUT SELECT, and set
the front panel TIMER MODE button to EXT
(external timer recording).
The unit’s power is turned off, and recording is
started by the signal from the external timer.
External timer
1 2
GND
IN
REC IN
GND TIME ADJ IN
TAPE END OUT
RESET
ALARM
EXT
TIMER
OUT
IN OUT
WARNING
/REC OUT
Auto OFF output connections and
recording output connections
The auto OFF output and recording output
connections are the same. Select between them
using ERROR WARN/REC OUT on the menu screen
shown on P7 TERMINAL OUTPUT SELECT.
Auto OFF output
When a problem has occurred in the unit, the alarm
device which has been installed externally is
triggered.
In this case, the error code appears on the display.
(See page 53.)
Recording output
When the unit is set to the recording mode, the alarm
device which has been installed externally is
triggered.
Alarm lamp
External
interface
Power OFF
Power OFF
External timer signal
Recording proceeds in the recording
mode which was set by menu screen P4
RECORDING MODE.
External timer
recording
Содержание AG-DTL1E