SVC 820-Tankless Gas Trouble Shooting Manual Page |
75
75
61 – Error Code Diagnostic Chart
YES
NO
NO
YES
YES
NO
Test DC voltage across black and red
wires on Molex connector “G”:
144 – 192 DC VOLTS
Is the DC voltage
OK?
Remove and reinsert connector “G”.
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 61:
Replace Control Board
Is the DC voltage
OK?
Press and hold down “MAX” button on Control Board
to activate Blower Motor. While Blower is running,
test DC voltage across black and white wires on Molex
connector “G”:
12 – 18 DC VOLTS
Press and hold down “MAX” button on Control Board
to activate Blower Motor. While Blower is running,
test DC voltage across black and blue wires on Molex
connector “G”:
4 – 10 DC VOLTS
Remove and reinsert connector “G”.
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 61:
Replace Control Board
Is the DC voltage
OK?
Replace Blower Motor
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 61:
Replace Control Board
Содержание PH2-20R DVSN
Страница 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Страница 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...
Страница 170: ... 170 matic Disassembly PHH 32ROF PHH 25ROF ...