IGNITER ROD Diagnostic Chart
YES
NO
NO
Check AC Volts across 2 grey wires on
connector “H” while unit is attempting to
ignite:
108 – 132 Volts AC
Attempt to operate unit again.
IF Igniter Rod does not spark and unit
malfunctions due to Error Code 11:
Replace Control Board
Replace Igniter Coil
YES
YES
Is the voltage
OK?
Does spark arc
across Igniter Coil
cable and Igniter
Rod?
Remove Igniter Coil cable from Igniter Rod. While
unit is attempting to ignite, hold end of Igniter Coil
cable 1/8” from end of Igniter Rod.
Make sure you hold Igniter Coil cable on the rubber
insulation while performing this check
Remove Igniter Rod and clean.
Reconnect Igniter Coil cable and Igniter Rod.
Attempt to operate unit again.
NO
Is spark visible
through sight
glass?
Replace Igniter Rod
Igniter Rod is ‘OK’
IF unit fails again due to Error Code 11:
IF flame IS visible, diagnose Flame Rods
IF flame is NOT visible, diagnose
Gas Control Valve
Содержание PH2-20R DVSN
Страница 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Страница 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...
Страница 170: ... 170 matic Disassembly PHH 32ROF PHH 25ROF ...