56 |
Page SVC 820 Tankless Gas Trouble Shooting Manual
56
24 – Error Code
Explanation:
Remote Control buttons were depressed for more than 20 seconds. IF you were manually holding down any
Remote Control buttons for more than 20 seconds, release the buttons and NO Error Code will be displayed. Unit will operate
normally. IF error code 24 is still displayed after releasing Remote Control buttons, continue to Remote Control diagnostics.
Diagnostic Checks:
•
Remote Control
REMOTE CONTROL DIAGNOSTICS
:
Visually inspect Remote Control wiring for damaged or
loose terminals.
1
Turn power OFF. Remove and reconnect Remote Control
wiring terminals at bottom of unit. Attempt to operate
unit again. IF 24 Error Code does NOT display, unit had a
loose connection.
IF 24 Error Code IS displayed, continue to diagnostic chart
on next page.
2
Hot Water Outlet
Cold Water Inlet
Remote Control
Wiring Terminals
Содержание PH2-20R DVSN
Страница 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Страница 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...
Страница 170: ... 170 matic Disassembly PHH 32ROF PHH 25ROF ...