5
Section 1.2 - Adjusting the Temperature
To adjust the system temperature higher, stop any hot water
fl
ow,
and press the Up Button until you reach the desired temperature
setting. See Figure 1.2.a.
NOTE: The temperature can only be raised above 112ºF if the water
fl
ow has been stopped, this is a safety feature of the system.
For temperature settings above 120ºF see the instructions in Sec-
tion 1.5 to increase the max temperature range.
Manifold System Operation
To adjust the system temperature lower, press the Down Button to
lower the temperature until you reach the desired temperature set-
ting. See Figure 1.2.b.
NOTE: You may lower the temperature while water is
fl
owing and
the heaters are in operation.
Figure 1.2.a - Raise Temperature
Figure 1.2.b - Lower Temperature
STANDARD TEMPERATURE SET POINTS in ºF
100
102
104
106
108
110
112
114
116
118
120
HIGH TEMPERATURE SET POINTS in ºF
125
130
135**
140
150
160
170
185*
*Max Temperature depends upon water heater model.
** Not available on some models.
Section 1.3 - Status Lights
The status lights on the remote consist of a “Burner On” indicator,
see Figure 1.3, and a Priority light.
The “Burner On” indicator will come on to show when only when the
system is heating water. This is regardless of the number of units
operating in the system.
The “Priority” light tells which remote control has priority over the
system in applications with multiple remote controls. This feature is
only available on single installation residential units.
Figure 1.3 - Raise Temperature
BURNER
INDICATOR
Show Status
of the
Burners
Section 1.4 - System Restart
To restart the system, stop any hot water
fl
ow, and press the Power
Button on the Remote Control Thermostat. See Figure 1.1. A Green
indicator in the power button will go out and the display will show
blank.
Disconnect the power from the MIC-185 and tankless water heaters.
Wait 30 seconds and apply power to all the tankless water heaters
fi
rst, then apply power to the MIC-185, the display will being to blink
dashes. Once the display has stopped blinking dashes, proceed
back to Section 1.1 to turn on the system.
- 141 -
Содержание PH2-20R DVSN
Страница 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Страница 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...
Страница 170: ... 170 matic Disassembly PHH 32ROF PHH 25ROF ...