- 124 -
Adjustment
Adjustment of Burner Control Assembly (PC Board)
The content on this page is intended for use by qualifi ed service personnel only.
PCB Replacement Procedure
WARNING: You will need to perform this procedure when you replace the PCB.
Without this adjustment, the water heater may not function properly.
WARNING: Improper adjustment, alteration, service or maintenance can cause property
damage, personal injury, or death.
Note: During the adjustment procedure if [EE] is displayed on the LED of remote control,
adjust again with caution. This means there was an error in the adjustment sequence.
NOTE: If the value number for the Maximum, Minimum and Slow Ignition manifold setting (01~39) were written down
on the front plate, record these numbers and skip the steps 3 ~ 5.
When replacing the printed circuit board (PCB), adjust as follows.
1. Find the SW1, SW2, SW3 buttons and DIP1 switch located at the top right hand side of the PCB. (See PCB Figure 1)
2. Record any DIP switches setting.
3. With old PCB installed verify minimum manifold pressure setting. The setting value will be displayed on the remote
control.
a. Without any water fl ow, press and hold down the Adjusting Button (SW3)
b. Momentarily press the Minimum Button (SW1)
c. Record the number that displays on the remote control ________________
d. Release the Adjusting Button (SW3)
4. Verify maximum manifold setting. The setting value will be displayed on the remote control.
a. Without any water fl ow, press and hold down the Adjusting Button (SW3)
b. Momentarily press the Maximum Button (SW2)
c. Record the number displayed on the remote control ___________________
d. Release the Adjusting Button (SW3)
ON
1
2
3
4
ON
OFF
ON
1
2
3
4
ON
OFF
1 2 3 4
1 2 3 4
DIP2
DIP1
MIN
MAX
ADJ
LED
DIP 1
DIP 2
Adjusting
Button (SW3)
Program
Chip
Maximum
Button (SW2)
Minimum
Button (SW1)
LED
Printed Circuit Board (PCB) - Figure 1
5. Verify slow ignition manifold setting. The
setting value will be displayed on the remote
control.
a. Find DIP1 and change DIP switch #1
setting of DIP1 to ON position. DO NOT
alter any other DIP switch.
b. Without any water fl ow, press the
Maximum Button (SW2), then
Minimum Button (SW1) within 2 seconds
and hold down both button for more than
5 seconds. The “P” is displayed on the LED
of remote control.
c. Release the Maximum Button (SW2) and
Minimum Button (SW1), then press and
hold down the Adjusting Button (SW3) to
change “P” to the value.
d. Record the number displayed on the
remote control __________________
e. Release the Adjusting Button (SW3)
f. Change the DIP switch #1 setting of DIP1
to OFF position. DO NOT alter any other
DIP switch.
6. Turn off power at remote control.
7. Disconnect power from water heater. Turn
off gas and water supply to water heater.
Содержание PH2-20R DVSN
Страница 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Страница 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Страница 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...
Страница 170: ... 170 matic Disassembly PHH 32ROF PHH 25ROF ...