UR210
UR210 Series
RETURN LINE FILTERS
s e r v i c e
i n s t r u c t i o n s
2
1 Specifications
Housing materials:
Head and Bowl: Aluminium alloy, painted external finish
Maximum operating pressure:
41 bar (600 psi)
Proof pressure:
62 bar (900 psi)
Minimum burst pressure:
165 bar (2400 psi)
Element collapse:
UE210 element 10 bard (150 psid) differential minimum
Operating temperature range:
-29° C to 120° C (-20° F to 250° F) with fluorocarbon seals
for petroleum based and specified synthetic fluids
60° C (140° F) maximum in HWCF, water-oil emulsion
or water glycol
Bypass valve setting options:
1.7 ± 0.2 bard (25 ± 3 psid) cracking pressure
4.5 ± 0.5 bard (65 ± 7 psid) cracking pressure
Seals:
Fluorocarbon
The actual operating conditions should be checked by the
user to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.
2
Receipt of equipment
The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to be
discarded.
3
General sources of information
3.1 For dimensions, operating parameters, assembly/
element part number, ordering information, notes,
performance data and specifications refer to datasheet.
3.2 This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.
3.3 Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.
4
Installation of housing
4.1 The filter can be installed in any attitude, but for ease of
servicing, it is recommended that it be installed vertically
with the bowl pointing downwards.
4.2 The minimum clearance required for element removal is:
76.2mm or 3” for all lengths. The UR210 Housing is
supplied without a filter element. For element installation
and servicing procedures, refer to Section 7.
4.3 Threaded differential pressure devices, when fitted,
must be torque tightened to 40 lbft or 54Nm. All visual
indicators must be clearly visible.
NOTE: The UR210 head is supplied with a machined
differential pressure warning device port, fitted with a plastic
shipping plug. If no differential pressure warning device is
ordered, the shipping plug must be removed and replaced with
a ‘B’ type blanking plug (HA9000-A104Z) and torque tightened
to 40lb/ft or 54Nm.
NOTE: Never place the port plug in this port without first
installing uniform size -014 O-ring in lower O-ring groove,
otherwise a small bypass flow will result, allowing contaminant
downstream of the filter element.
4.4 Mount the filter assembly in position using four
5/16-18 (‘A’ ports) or M8 x 1.25 (‘C’ ports) bolts in the
holes on the head mounting pads. Torque bolts to
10-14 ft/lb or 14-19 Nm.
4.5 Use a check valve downstream of the filter if there is a
possibility of reverse flow.
4.6 Install the filter housing using additional piping/valving
to allow complete filter assembly bypass if filter
maintenance is required without system shutdown. This
series is not available in a duplex or service bypass
configuration.
NOTE: Piping supports should be provided as close as is
practicable to the port connections in order to minimize
external loads. This filter assembly must not be electronically
isolated from the users earthing system. This filter assembly
must be earthed by connecting the users earthing system to
one of the inlet/outlet connections.
4.7 Connect lines or hoses to housing inlet and outlet ports.
CAUTION:
Maximum surge flow should not exceed 1.3 times
normal flow.
WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER
ON NAMEPLATE AND NOTED IN DATA SHEETS:
USE OF INCORRECT FITTINGS OR ADAPTORS CAN
CAUSE FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.
CAUTION:
Reverse flow through filter element will cause damage.
CAUTION:
Never operate the filter unless warning device port is
sealed.
Содержание UR210 Series
Страница 6: ...6 Figure 2 UR210 UR210 Series RETURN LINE FILTERS service instructions 1 2 5 4 Not shown 3 6 7 ...
Страница 7: ...7 UR210 UR210 Series RETURN LINE FILTERS service instructions ENGLISH ...
Страница 9: ...UR210 UR210系列 M ESIUR210CN S c CN Simplified UR210使用说明书 使用说明书 中文 SIMPLIFIED EN ES DE FR JP CN IT KR ...
Страница 14: ...14 UR210 UR210系列 回流管过滤器 使用说明书 图2 1 2 5 4 未显示 3 6 7 ...
Страница 15: ...15 UR210 UR210系列 回流管过滤器 使用说明书 中文 SIMPLIFIED ...
Страница 17: ...UR210 UR210系列 M ESIUR210CN T c CN Traditional 中文UR210使用說明書 使用說明書 中文 TRADITIONAL EN ES DE FR JP CN IT KR ...
Страница 22: ...UR210 UR210系列 返回管線過濾器 使用說明書 22 圖2 1 2 5 4 未顯示 3 6 7 ...
Страница 23: ...UR210 UR210系列 返回管線過濾器 使用說明書 23 中文 TRADITIONAL ...
Страница 30: ...30 Abbildung 2 UR210 Baureihe UR210 RÜCKLAUFFILTER Wartungsanleitung 1 2 5 4 Nicht dargestellt 3 6 7 ...
Страница 31: ...31 UR210 Baureihe UR210 RÜCKLAUFFILTER Wartungsanleitung DEUTSCH ...
Страница 39: ...39 UR210 Series UR210 FILTROS DE LÍNEA DE RETORNO instrucciones de mantenimiento ESPAÑOL ...
Страница 46: ...46 Figure 2 UR210 Série UR210 FILTRES RETOUR instructions de service 1 2 5 4 Non illustré 3 6 7 ...
Страница 47: ...47 UR210 Série UR210 FILTRES RETOUR instructions de service FRANÇAIS ...
Страница 55: ...55 UR210 Serie UR210 FILTRI SULLA LINEA DI RITORNO istruzioni d uso e manutenzione ITALIANO ...
Страница 57: ...UR210 M ESIUR210JNc アフターサービス説明書 JN UR210アフターサービス説明書 UR210シリーズ 日本語 EN ES DE FR JP CN IT KR ...
Страница 62: ...UR210 UR210 シリーズ 戻りラインフィルタ アフターサービス説明書 62 6 ᅒ2 UR310 UR310ࠪ ᚯࠅ ࠗࡦࡈࠖ ࠕࡈ ࠨ ࡆࠬ ᦠ 1 2 5 4 図示せず 3 6 7 ...
Страница 63: ...UR210 UR210 シリーズ 戻りラインフィルタ アフターサービス説明書 63 日本語 ...
Страница 65: ...UR210 M ESIUR210KRc KR UR210 서비스 지침 UR210 시리즈 서비스 지침 한국어 EN ES DE FR JP CN IT KR ...
Страница 70: ...UR210 UR210 시리즈 리턴 라인 필터 서비스 지침 70 그림 2 1 2 5 4 표시되지 않음 3 6 7 ...
Страница 71: ...UR210 UR210 시리즈 리턴 라인 필터 서비스 지침 71 한국어 ...