ZENIT
80
+
TYPE TUBE RADIANT HEATER
Instructions for Installation and Servicing
8
1. The piping system is completed by slipping the burner tube and radiant heat tubes into each other.The burner tube (the tube which
is provided with clamp) is fixed to the burner.To this one connect all the radiant heat tubes.
2. Apply evenly the sealant/adhesive in the inner part of the expanded end of the tube you whish to connect. The sealant/adhesive
must be applied in 80mm lenght, from the beggining of the expanded end of the tube.
3. Insert it to the not expanded end of the next radiant tube, and so on...
4. Then to scure it using 3 selfdrilling screws, 120° apart each other and never place it at the top, always at the bottom or at the
sides.
Assembly
Sealing material
4. picture: Tubes join
5.picture: Turbulator
Sealing material
3000
75
80
Sliding direction
5. Turbulator (bent plate) must be always placed in the last radiant heat tube, before flue gas outlet.