background image

ZENIT 

80

+

 

TYPE TUBE RADIANT HEATER 

Instructions for Installation and Servicing

3

Other standards can give you directions in terms of proper using of natural and propan gas as follows: leading/piping, storing etc.! 

Concerning the detailed content of these standards the local Bureau of Standards can help.

Carbon- monoxide poisoning: 

The initial symptons of carbon-monoxide poisoning are similar to influenza namely headache, dizziness 

and/or nausea! If these symptons are observed in that case the appliance probably does not work satisfactorily! First of all go fresh air, 

ventilate the rooms and have the appliance investigated!

Propan-gas:

The propan-gasis odorless! Mercaptan-derivative as scented component is mixed into the gas to be able to observe the 

possible escape! In spite of the typical smell is not felt the propan gas can be present in the environmental air in case of escaping!

GENERAL SAFETY NOTICES

   Disregard of instructions and notices of this Manual can cause serious bodily injuries or damages 

as follows: burning, explosion, suffocation, carbon monoxide poisoning, electric shock and in extreme 

case death! 

This appliance can only be used and serviced by such persons who understood and follow the instruc-

tions of this Manual

If you need help or information concerning the appliances – for example installation guide or labels 

etc. – in that case contact with the manufacturer!

This appliance must not be used by children and mentally or sensitively deficient persons! Take care 

that the children do not handle it and do not  play with devices!

ATTENTION! Fire, burning, inhalation and explosion hazard! Keep all flammable objects as follows 

building materials, papers, or carton unites away from heater according to the instructions! Never 

use this appliance in such rooms where there are flammable volatile materials or the following mate

-

rials, which can get into the device: petrol, solvent, thinner, fine grained dusty or unknown chemical 

materials!

ATTENTION! This appliance can not be used in domestic circumstances or mobile home!

ATTENTION! For your safety, if you smell gas do the followings: 

-   

Open windows.

Do not try to light any appliance.

Do not use electrical switches.

Do not use any telephone in your building.

Leave the building.

Immediately call your local gas supplier after leaving the building. Follow the gas supplier’s  

  

instructions.

If you cannot reach your gas supplier, call the Fire Department.

Read and understand this manual thoroughly before installing starting or servicing this equipment. The 

improper installation or using can cause serious damages! Keep this manual in a safe place in order to 

obtain information in case of incidental problems!

 

 

 

 

 

1.

  

Safety information

The ZENIT 

-type tube radiant heater appliances have been developed and certified in comp  liance with EN 416 standard and qua

-

lified for heating of industrial rooms! The function of these heater appliances to ensure heating of appointed workplace temporarily or 

continuosly! In case of proper using the appliance guarantees safety and energy-saving operation! The combustion products issued du-

ring combustion process leave through the flue system into the open air. In case of further possible questions regarding the applicabi  lity 

please turn to the local Fire Protection Office!

Содержание ZENIT 80+ Series

Страница 1: ...www pakole com Appliance types ZENIT 80 12 42 Linear and U form types 008_007_011_180712_V001_EN PROPANE OR NATURAL GAS FIRED ZENIT TYPE TUBE RADIANT HEATER Instructions for Installation and Servicin...

Страница 2: ...connection 28 Regulatory options 29 Electrical connection scheme of SIT 579 DBC type automatic burner control 29 Optional accessories 29 Protective distances 30 Combustion air supply 32 6 Exhaust sys...

Страница 3: ...play with devices ATTENTION Fire burning inhalation and explosion hazard Keep all flammable objects as follows building materials papers or carton unites away from heater according to the instruction...

Страница 4: ...st pipes Keep away the children and animals from the equipment Never service mend such devices which are hot and during operation or electrical charged Never mount such air duct unit on front or back...

Страница 5: ...rer office or the closest dealer www pakole com and ask for further informations ATTENTION COMPULSORY EARTHING ATTENTION ONLY QUALIFIED PERSON CAUTION DANGER CAUTION ELECTRIC SUPPLY According to the i...

Страница 6: ...ard board box The unpacking process of the appliance unload the burner the tubes and the accesories from the card board box do not remove the protection cap from the burners gas connection or from the...

Страница 7: ...ger Combustion air Reflector Electrical connection Components of I form tube radiant heater assembly distances Combi hanger Burner Reflector hanger Tube connection U element Components of U form tube...

Страница 8: ...xpanded end of the tube you whish to connect The sealant adhesive must be applied in 80mm lenght from the beggining of the expanded end of the tube 3 Insert it to the not expanded end of the next radi...

Страница 9: ...sition at the factory The burner must be connected to the free end of the clamp where the unexpanded tube part must be inserted untill the bumper screw After finishing the inserting process the screws...

Страница 10: ...to its final position In case it is not possible becuse of the weight of appliance and the local conditions then it is worth mounting it in several parts and making the last connections in mounted pos...

Страница 11: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 11 Assembling the first unit Fixing aluminium profiles With M6 screw...

Страница 12: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 12 Fixing of Tube holder Assembling the until set with burner to the wall With M8 screw...

Страница 13: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 13 fixing of suspension points Positioning burner tube and radiant tube insertion of inside reflector...

Страница 14: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 14 Insertion of external cover reflector Insertion of upper holders...

Страница 15: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 15 Assembling the second parts Assembling aluminium profiles M6 screw...

Страница 16: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 16 Insertion tube holders Inserting radiant tube Inserting screw With M8 screw...

Страница 17: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 17 Positioning reflector Positioning of utside reflector Fixing holders...

Страница 18: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 18 Assembling the first and the second part of appliance 1 2 3 Assembling insulated reflector...

Страница 19: ...urner tube During assembling of straight system the installation of 1 pc 90 elbow is allowed but it must be placed minimum 6m far from the burner U form tube radiant heater appliance see fig 3 At the...

Страница 20: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 20 Assembling the third element Assembling the middle part...

Страница 21: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 21 Aluminium profile Fixing tube holder Instering radiant tube...

Страница 22: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 22 Inserting of insulated reflector inserting screw holder...

Страница 23: ...YPE TUBE RADIANT HEATER Instructions for Installation and Servicing 23 Assembling of cover plates to the U element positioning 3 elements 1 2 3 Positioning and fixing the first element with self drill...

Страница 24: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 24 2 Positioning the second element 3 Positioning and fixing the third element with self drilling screw...

Страница 25: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 25 Assembling last element Assembling last part of insulated reflectors Insertion cover reflector...

Страница 26: ...The pressure regulator can be installed before each appliance or centrally namely one piece into the gas supply pipe In case of unique solution namely there is pressure regulator before each applianc...

Страница 27: ...grounded power supply system If the above instructions are not followed that can lead to death heavy injuries or property demages PLEASE CHECK THE EARTHING VIGY ZAT VESZ LY VIGY ZAT RAM ELL T S FIGYE...

Страница 28: ...e control begin degrease the performance of appliance without any stage continuously to 50 of performance where the control keeps it during this time till the temperature reaches the setted temperatur...

Страница 29: ...atic burner control Regulatory options Recommended temperature controllers for the appliance these can be purchased at the appliance manufacturer Optional accessories Thermostat If the switcher positi...

Страница 30: ...th the valid standards Disregard of these instructions can result in death injury or property damage Protective distances 15 picture Explanation of heat radiated area Protective distances to be kept c...

Страница 31: ...ter determining the number and exact position of appliances and hangers you have to provide for hanging them at a minimum of 400 mm hanging chains for example This is necessary so it does not hinder t...

Страница 32: ...0mm and should not exceed 15 m in lenght Maximum two 90 elbows may be used 23 picture Outside combustion air supply Inhale opening End plate Exhaust arrangements of combustion products Flue channel to...

Страница 33: ...stem must be at least higher than 1 m from openings sucking hole of vent etc of force assisted ventilation systems The bottom side of exit opening must be minimum from 30 cm any kind of frontal wall p...

Страница 34: ...iances with common exit flue B33 28 picture Common flue vent set Zenit Tube Radiant Heaters Zenit Tube Radiant Heaters 29 picture Side wall flue vent set Exhoust out taking combustion air intaking A C...

Страница 35: ...be heater Side wall flue vent and combustion air intake element 100mm INOX combustion Air tube Vertical flue vent element 31 picture Closed burning flue vent system d common flue vent set for closed b...

Страница 36: ...noid valve whether the set up pressure nozz le pressure is suitable for the type of gas At Natural gas depending on output 8 6 9 5 vagy 10 mbar At S gas depending on output 8 6 10 11 11 8 vagy 12 5 mb...

Страница 37: ...d heat radiant tubes by a survey In case there is lack of sealing colouring shows it c Check the condition of reflectors if necessary clean them Clean them by a soft cloth or diluted detergent d Check...

Страница 38: ...the condition of differential pressure switch e Checking the presence of protective ground f Supervision of electrical connection g Supervision of combustion air fan Check wheter the wheel of fan is a...

Страница 39: ...ir is not removed sufficiently from gas pipe Nozzle pressure is not suitable Necessary air flow for burning is not suitable Turn on the gas supply valve Remove the air from the pipe Check the input an...

Страница 40: ...13 4 20 4 11 6 x x x x x x ZENIT 80 22 14 7 21 9 12 8 x x x x x x ZENIT 80 24 16 24 4 14 8 x x x x x x ZENIT 80 26 17 4 26 2 15 9 x x x x x x ZENIT 80 28 18 7 28 4 16 8 x x x x x x ZENIT 80 30 20 1 3...

Страница 41: ...4 1 83 1 07 1 77 1 03 ZENIT 80 24 16 24 4 14 8 2 56 1 55 2 04 1 24 1 97 1 2 ZENIT 80 26 17 4 26 2 15 9 2 75 1 67 2 19 1 33 2 12 1 29 ZENIT 80 28 18 7 28 4 16 8 2 98 1 76 2 37 1 4 2 3 1 36 ZENIT 80 30...

Страница 42: ...0 Minimum heat output as percentage of nominal heat output 60 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 64 1 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Страница 43: ...10 Minimum heat output as percentage of nominal heat output 60 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 1 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 44: ...20 Minimum heat output as percentage of nominal heat output 60 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 9 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 45: ...90 Minimum heat output as percentage of nominal heat output 60 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 7 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 46: ...60 Minimum heat output as percentage of nominal heat output 58 4 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 3 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 47: ...70 Minimum heat output as percentage of nominal heat output 54 9 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 7 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 48: ...20 Minimum heat output as percentage of nominal heat output 57 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 6 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 49: ...10 Minimum heat output as percentage of nominal heat output 57 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 9 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 50: ...ne by not authorized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly...

Страница 51: ...ZENIT 80 TYPE TUBE RADIANT HEATER Instructions for Installation and Servicing 51...

Страница 52: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 http www pakole com E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...