Section 150-232-100
Revision 01
Page 9
Figure 4. HLU-232, List 1D DB-9 Pin-Outs. A standard RS-232 DB-9, female connector on the front panel provides
access to the menu interface feature via a dumb terminal.
4.02 The HLU 232’s STATUS LED flashes RED for the duration of a minor alarm condition. The H1(2)ES and DS1
alarms can be inhibited by selecting NONE for the ESAL system option. See Section 8 for System Settings
information. The MAL1(2) alarm can be disabled by setting the margin alarm threshold to 0. A minor alarm can be
retired by executing the Alarm Cut-Off (ACO) option. This is accomplished by pressing the SEL button on the front
panel when an alarm is active. This turns the alarm off and replaces the “ALRM” message with the “ACO” message.
The second part of the “ALRM” message, which defines the cause of the alarm, remains. Both messages remain
until the alarm condition clears or another alarm occurs.