TABLE 2. SYSTEM OPTION SETTINGS (CONTINUED)
Mode
Selection
Description
FRMG
AUTO*
Configures HiGain to operate in an auto-framing (AUTO) mode in which it
continuously searches the input DS1 bit stream for a valid SF or ESF frame pattern.
This feature is required for fractional DS1 applications (DS0 blocking) where it
insures proper channel time slot alignment. While HiGain can also process
unframed data in this AUTO mode, it is recommended that the UNFR mode be used
for all unframed applications. Using the AUTO mode for unframed applications runs
the risk of detecting “pseudo valid” frame sequences, which can affect the data
integrity.
UNFR
Configures HiGain to operate in an unframed mode. This mode disables the auto
framing process and forces HiGain to function as a transparent bit pipe.
HAIS
2LP*
Causes HiGain to transmit the AIS signal at both the HLU & HRU DS1 output ports
when both of the HDSL loops are not in sync (LOSW).
1LP
Causes HiGain to transmit the AIS signal at both the HLU & HRU DS1 output ports
when either of the two HDSL loops is not in sync (LOSW) or if a minor alarm
occurs.
SAIS
ENA*
Causes the HRU to transmit the AIS signal towards the Customer Interface (CI)
when in NREM or SMJK loopback.
DIS
Causes the List 6 HRU to transmit the signal from the network towards the CI and
the List 7 to open and terminate the NI when in the NREM or SMJK loopback state.
The AIS signal towards the CI is turned off.
CONF
YES
Confirms that all 12 of the above operating modes are to be updated to their current
selections.
NO*
Prevents the most recently selected operating mode selections from being updated.
They remain as they were before the system option settings mode was entered.
MARG
0 to 15 dB
(4*)
The Margin Alarm Threshold can only be set via the RS-232 maintenance port with
an ASCII terminal. See Figure 10. It determines the minimum allowable margin
below which a minor alarm will occur.
DS0
BLK
The DS0 blocking option can only be set via the RS-232 maintenance port with a
dumb terminal. See Figure 10. The 4-character HLU front panel LED readout only
displays the status of the blocking option. BLK indicates at least one channel is
blocked.
NONE*
NONE indicates no channels are blocked.
*Indicates HLU-232 factory settings. HiGain can be set to these default settings by pressing the SEL button for 6