TABLE 19. HLU-232 A3LB TEST PROCEDURES
Step
Action
1
The HLU-232 List 1D can be looped back by sending the Addressable Office Repeater (AOR) LPBK
activation code 1111 1111 0001 1110 (FF1E) for at least five seconds. This causes the HLU-232 List 1D
to enter its NLOC state shown in Figure 19. The display on the HLU-232 List 1D alternates between
NLOC (network local loop) and the margin displays. The Loopback Time-out option, which is user
settable to NONE, 20, 60 or 120 minutes, determines the duration of this loopback unless it is overridden
by the reception of a second identical 16-bit loop-up command before the timer expires. When this time-
out override state exists, the only way to loop the HLU-232 List 1D down is to issue one of the three loop-
down commands listed in Step 2. The automatic time-out mode is restored during subsequent loopback
sessions.
2
The following list summarizes the codes required to execute all the HiGain system loopbacks shown in
Figure 19. Note that all code sequences must be present for at least five seconds.
ABBREVIATIONS USED BELOW:
LU = LoopUp
LD = LoopDown
NI = Network Interface
CI = Customer Interface
ESF-DL = Extended Super Frame Data Link
ADDRESSABLE 3 (A3LB) REPEATER LOOPBACK COMMANDS
Position
Name
Code
HLU-232 LU FROM NI
NLOC
1111(F)*1111(F)0001(1)1110(E)
HLU-232 LU FROM CI
CREM
0011(3)1111(F)0001(1)1110(E)
HDU-451 DOUBLER 1 FROM NI
NDU1
1111(F)*1111(F)0000(0)0100(4)
HDU-451 DOUBLER 1 FROM CI
CDU1
0011(3)*1111(F)0000(0)0100(4)
HDU-451 DOUBLER 2 FROM NI
NDU2
1111(F)*1111(F)0000(0)0101(6)
HDU-451 DOUBLER 2 FROM CI
CDU2
0011(3)*1111(F)0000(0)0101(6)
HRU-412 LU FROM NI
NREM
1111(F)1111(F)0000(0)0010(2)
HRU-412 LU FROM CI
CLOC
0011(3)1111(F)0000(0)0010(2)
HRU-412 LU FROM NI
SMJK
11000 11000 11000 ...
HRU-412 LU FROM NI
SMJK
100000 100000 100000 ...
HRU-412 LU FROM NI (ESF-DL)
SMJK
1111(F)1111(F)0100(4)1000(8)
HLU & HRU LD FROM NI OR CI
11100 11100 11100 ...
HLU & HRU LD FROM NI OR CI
100 100 100 ...
HLU & HRU LD FROM NI OR CI
(ESF-DL)
1111(F)1111(F)0010(2)0100(4)
Note: The left most bit arrives first in all sequences. The detection algorithm functions reliably with a
random 10
-3
Bit Error Ratio (BER) on the facility. *This is the HEX number for the 16-bit binary code.
3
All of the above loopbacks can also be initiated from the front panel of the HLU-232 List 1D with the
MODE and SEL buttons (Section C Paragraph 3.10).