TABLE 10. HLU-232, LIST 1D 4-CHARACTER FRONT PANEL MESSAGES
Message
Full Name
Description
CREM
Customer Remote
Loopback
Signal from customer is looped back to customer at HLU-232.
NLOC
Network Local
Loopback
DSX signal is looped back to DSX at HLU.
CLOC
Customer Local
Loopback
Signal from Customer is looped back to customer at HRU-412.
NREM
Network Remote
Loopback
DSX signal is looped back to DSX at HRU.
SMJK
Remote Smartjack
Loopback
DSX signal is looped back to DSX at HRU by the HRU smartjack module.
TLOS
Transmit Loss Of
Signal
HRU is in a logic loopback state caused by a loss of its T1 input from the CI, if
enabled at the HRU via its TLOS switch option.
FERR
Framing Bit Error
Occurred
Framing bit error occurred at HLU T1 input.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the T1 input to the HLU-232.
SIG1 or
SIG2
Signal 1 or Signal 2
The HLU & HRU transceivers are trying to establish contact with each other.
ACQ1 or
ACQ2
Acquisition 1 or
Acquisition 2
The HLU & HRU multiplexers are trying to establish synchronization over each
loop.
H1ES
HDSL CRC Error
Channel 1
HLU HDSL Loop 1 CRC error.
H2ES
HDSL CRC Error
Channel 2
HLU HDSL Loop 2 CRC error.
ARM
HiGain System
ARMED
Armed to respond to Intelligent Repeater Loop Codes.
ACO
Alarm CutOff
A minor alarm has occurred, and been retired to an ACO condition, by pressing
the SEL button on the HLU front panel.
SELF
TEST
Self Test
The HLU is in self test mode. This occurs every power ON/OFF cycle.
ALRM
Alarm Condition Exists
A minor alarm condition is in effect.
1=xx or
2=yy
HDSL Loop Margins
Indicates the power of the received HDSL signal on each Loop relative to
noise. Any value of ‘06’ or greater is adequate for reliable system operation.
PWR
FEED
SHRT
Power Feed Short
Indicates a short between the 2 HDSL pairs. This same message can occur
with an HRU that is drawing the correct amount of power over good cable pairs
but cannot communicate with the HLU.
Table continued on next page