Section 5
LABELING UNIT
-
32
-
English
F
412
0501
00.fm
ID
M
version:
Module 40/60/90/120
CLEANING THE REEL CARRIER DISKS
Important
Do not use oils or hydrocarbon-
based solvents (e.g. petrol, spirit or
the like) to clean the transparent
disks, since they could be damaged.
Clean with a soft cloth dipped in a
neutral detergent (soap).
Danger - Warning
Before acting on any electric part, disconnect the
labelling unit switchboard upstream.
Any necessary intervention with the switchboard
connected to the power supply shall be carried out
by a qualified and authorised electrician.
GENERAL PROBLEMS
FAULT FINDING INSTRUCTIONS
PROBLEM
CORRECTIVE ACTION
The unit is not working: no labels are
ejected and the main switch pilot light
is off.
Check that the main switch is enabled.
Check connection of the unit to the power supply network upstream.
Check that the safety fuses of the network voltage supply, as shown in the
electric diagram, are efficient; otherwise, replace them with new fuses with the
same capacity and features.
The unit is not working: no labels are
ejected, the main switch pilot light is
on, but the other pilot lights are off.
Referring to the electric diagram, check that the safety fuses of the 24-VDC
feeder are efficient; otherwise, replace them with new fuses with the same
capacity and features.
If the fuses are working and in good order, check operation of the 24-VDC
feeder with the switchboard under voltage by measuring the output voltage with
a voltmeter and observing the feeder pilot lights (to check that they are on).
Replace the feeder with an original spare feeder, if necessary.
Check that the fuse on the PL001 card is working and replace it with another
fuse with an equal capacity and features, if necessary.
IDM-41200603100.tif