background image

37

TRNT.BODYA

100000457   180118-40

Installer information

 Replacement Parts 

       

TRENTON SALES CODES

 

 

 

DESCRIPTION    SALES CODE

Trenton unit complete
Metalic Black ................................................ 12020003
Antique White ............................................... 12020001
Majolica Brown ............................................. 12020002

 

Optional 

Trenton LP Conversion Kit ............................ 12180005
Direct Vent Terminal “Snorkel” ...................... 11270002 

Replacement

Trenton Door with glass ................................ 80001787
Trenton Screen.............................................. 80000628
Trenton Control Tray Complete ..................... 80000608
Trenton Panel Set Painted ............................ 80001867
Trenton Burner .............................................. 80002056
Trenton Log Set with Embers ....................... 80000627
Trenton Blower Right .................................... 80000905
Trenton Blower Left ...................................... 80000904
Trenton Light Housing with Bulb .................. 80000626
Trenton Decorative Tinted Glass Kit ............. 80000623
SIT Remote Transmitter ................................ 80000191
SIT Pilot Assembly ........................................ 80000193 

Replacement Cast Iron Painted

Kit ................................................................. 80002066
(Top)   
(Side L)   (Side R)
(Top Grill)   
(Ashlip)
(Legs - Set) 

Replacement Cast Iron Antique White

Kit ................................................................. 80002063
(Top)        (Front)
(Side L)    (Side R)
(Door L)   (Door R)
(Ashlip)
(Legs - Set) 

Replacement Cast Iron Maj Brown

Kit ................................................................. 80002064
(Top)       (Front)
(Side L)   (Side R)
(Door L)  (Door R)
(Ashlip)
(Legs - Set) 

Содержание Trenton

Страница 1: ...on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used This appliance is suitable for installation in a bedroom or bed sitting room Do not store...

Страница 2: ...ol 10 Continuous Pilot Intermittent Pilot CPI IPI selection 10 Remote dimmer control Light 10 Low Battery Power Detection 11 Remote Transmitter 11 IFC Module Receiver 11 Warnings and Cautions 11 Maint...

Страница 3: ...t terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBST...

Страница 4: ...enton gas stove without rst reading and understanding this manual Any installation or operational deviation from the following instructions voids the Paci c Energy Fireplaces Warranty and may prove ha...

Страница 5: ...ysical barrier is recommended if there are at risk individuals in the house To restrict access to the gas stove install an adjustable safety gate to keep toddlers young children and other at risk indi...

Страница 6: ...rrent Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A in the USA Installation Requirements The Trenton gas stove installation and venting mus...

Страница 7: ...a simple button layout and informative LCD display Figure 1 The remote transmitter is powered by 3 AAA type batteries A mode key is provided to index between the features and a thermostat key is used...

Страница 8: ...press the ON OFF Key on the Remote transmitter The Remote transmitter LCD display will only show the room temperature Figure 3 and Figure 4 At the same time the Receiver module will turn off the gas s...

Страница 9: ...t temperature is now displayed Figure 10 To adjust the set point press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter The Sm...

Страница 10: ...tion press the Mode Key Figure 1 to index to the CPI mode icon Figure 15 Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI F...

Страница 11: ...IFC batteries are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC board When the batteries are...

Страница 12: ...ve media such as logs and embers Inspect decorative media and burner assemblies for soot buildup If excessive buildup of soot is present have a quali ed service person inspect and adjust unit for prop...

Страница 13: ...several tries push the On Off switch for the fireplace to OFF turn off all electric power to the fireplace and call your service technician or gas supplier Note Sufficient time must be allowed for air...

Страница 14: ...BODYA Installer information Trenton Gas Stove Dimensions Dimensions Height 30 5 8 inches Width 26 3 4 inches Depth 21 15 16 inches Height to center of Flue Outlet 24 inches 26 3 4 30 5 8 21 15 16 24 F...

Страница 15: ...onal oor protector Only requirement is that the oor be stable and strong enough to support the stove Note on corner placement Refer to minimum clearances as shown in Figure 21 Figure 22 Refer to Figur...

Страница 16: ...the vent terminal must be maintained as shown in Figure 23 and the Roof Pitch Table Measure clearances to the nearest edge of termination hood NOTE Vent terminal must not be recessed NOTE LOCAL CODES...

Страница 17: ...zontal vent run by 2 feet Ensure vent pipe is properly supported Damper Note The damper position is factory set to the closed position Every venting con guration is different and the damper setting ma...

Страница 18: ...top of chimney apply a bead of caulking to top of clay liner Slip vent terminal over liner and secure in place with lateral retaining bolts 5 For larger chimneys ashing will need to be constructed acc...

Страница 19: ...nal Direct Vent Termination Snorkel Note For proper operation the Snorkel must be oriented so that the vent inlet and outlet are located at the bottom end of the unit as shown in the side view of this...

Страница 20: ...ion the Snorkel correctly so that the drain ports are located at the bottom of the unit Exterior facing or siding can butt right up to the sides of the unit and can extend up to 1 from the wall to whi...

Страница 21: ...A N A SV4EBR90 4DT EL90S 4DT EL90SB 46DVA E90 46DVA E90B 90 Elbow Swivel N A N A 4D90L 4D90LB SV4E90 SV4EB90 N A N A N A N A NOTE Mixing venting components from different manufacturers is inadvisable...

Страница 22: ...certi ed venting for this gas stove See charts on page 21 for a list of approved venting components Figure 32 Co axial venting components Trenton Gas Stove Rear Component Right blower fan Gas supply...

Страница 23: ...Figure 34 Please see the gas supply section on page 34 of the manual for requirement of the gas supply Electrical connection An IEC power cord is provided for connection to a standard wall outlet Not...

Страница 24: ...re 36 Make sure that the latticed oval panel in the center of the top cover does not slip off as it is not fastened to the larger cover 2 Raise the glass door and safety screen cover Figure 37 and lif...

Страница 25: ...that it can be removed Figure 40 3 Remove the glass door together with the retainer frame that it is af xed to Log set pieces The large rear log Figure 41 comes wrapped separately from the smaller log...

Страница 26: ...Log Set Installation 3 Fit the hole in the back of the 2nd log Figure 47 over the post located on the left hand side of the rst log indicated by arrow Figure 47 Once 2nd log is mounted to the rst log...

Страница 27: ...ts underside which will t onto a protruding tab on the burner Inset of tab 5 Place 4th log as shown in Figure 49 The black charcoal side of the piece must face inwards This log will act as a support f...

Страница 28: ...Lower the glass door frame into place Figure 53 making sure that the frame ts into the horizontal slot on the oor of the rebox 2 Align the glass door frame laterally so that its protruding positioning...

Страница 29: ...acing toward the log set once it is in place Figure 56 shows the front side of the safety screen This side must be facing the doors once it is in place The safety screen frame is not square and so it...

Страница 30: ...top of the screen mesh once the holder is lowered into position Screen mesh Screen mesh Figure 61 shows the screen mesh holder in place with the holder channel keeping the screen mesh in its proper po...

Страница 31: ...7 The glass plate tray is located underneath the Trenton Figure 62 and is held in place by two wing nuts one on each side of the tray Changing the glass plate 1 The glass plate is easily installed fro...

Страница 32: ...ystem for the first time Operating Procedure The Pro ame 2 Integrated Fireplace Control IFC module is a device that allows automatic ignition and pilot ame supervision and commands the functions of th...

Страница 33: ...using liquid propane Venturi adjustment is accessible through an opening in the rear cover See location on Figure 33 on page 22 Some adjustment may be required Damper Adjustment c losed open Figure 68...

Страница 34: ...The gas stove input rating is shown in the chart below A drip leg must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within...

Страница 35: ...gauge to the test ports 4 Turn gas supply back on and verify gas pressure with the gas stove lit and on its highest setting 5 After testing is nished turn off gas supply remove the pressure gauges and...

Страница 36: ...talling the new ori ce Loctite 567 Thread Sealant needs to be applied to the threads of the new ori ce to ensure a proper seal when installed To replace the pilot ori ce remove the pilot hood which is...

Страница 37: ...0608 Trenton Panel Set Painted 80001867 Trenton Burner 80002056 Trenton Log Set with Embers 80000627 Trenton Blower Right 80000905 Trenton Blower Left 80000904 Trenton Light Housing with Bulb 80000626...

Страница 38: ...ion Wiring Diagram Cautio n Labe l all wire s prio r to disc o nne c tio n whe n se rvic ing c o ntro ls Wiring e rro rs c an c ause impro pe r and dang e ro us o pe ratio n Ve rify pro pe r o pe rati...

Страница 39: ...39 TRNT BODYA 100000457 180118 40 Installer information Rating Label T he Rating labe l as sho wn is lo c ate d o n the re ar o f the g as sto ve...

Страница 40: ...duction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pacificenerg...

Отзывы: