Solid Fuel Stoves Manual. Issued - 18/07/22
LX
LUXIMA
SOLID FUEL HEATING STOVE
Multi-fuel version, and Wood-only version
PLXMF Multi Fuel Stove
PLXWB Wood Stove.
PLXMFT Multi-Fuel
Deluxe
Stove
PLXWBT
Wood Stove
INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !
This stove exceeds the safety and performance requirements of Harmonised Standards for Intermittent burning solid fuel
roomheaters for installation with a single dedicated chimney.
Independent thermal and emissions testing by SGS Environmental Laboratory in 2019, CEN Notified Body EU0608 UK0120
Conforms to BS EN13240:2001+A2 2004,
Emissions tested and certified to BS EN16510-1, 2019
Fuel
Wood (Beech)
Multi-fuel configuration with grate
and ashpan
Wood (Beech)
Wood-only configuration with
flat fuel bed
Test Cycle
1.15kg over 0.75hrs
1.15kg over 0.75hrs
Settings
Primary 0, 2nd 1/3 open
Primary 0, 2nd 1/3 open
Flue Draught Pa (ins WG)
12 (0.05wg)
12 (0.05wg)
Efficiency %
75.4
74.3
Recommended Rating kW
4.9
4.9
Mean Flue Gas Temp Rise ºC
292
261
Minimum air entry requirement
2700 mm²
Minimum Clearance to combustibles (allow
min 150mm to non-combustibles)
500 mm
Emissions
as if O
2
=13%
NOx mg/m³
120
149
CO %
0.07
0.12
CxHy mg/m³
52
95
Gas flow g/sec
4.6
4.6
Smoke Emission mg/m³
37
34
Other fuels
Anthracite, manufactured smokeless fuels, peat, lignite
I declare that this information is true, these products meet the requirements of Harmonised Standards and are fit for sale.
Signed on behalf of the manufacturer by Glyn Hughes, Design Engineer, in the European Union and in Northern Ireland at
Room 76255, PO Box 1213, Belfast BT1 9JY and in the UK at Denver House, Winster DE42DH 22. Jun. 2021
Read these instructions ! Use only recommended fuel !
This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of Building Law. It must be left with
the householder where it can easily be found.
INSTALLED AT LOCATION:
BY:
EMERGENCY CONTACT:
British Fire Manufacturers
Trentham Lakes, Stoke on Trent, Staffordshire, England ST4 4TJ
These stoves may be used in smoke control areas when operated strictly in accordance with these instructions and with
Soliftec Smoke Advice Sheet No1 (
www.soliftec.com/smokeadvice.htm),
when burning:
UK:
Untreated wood logs or authorised smokeless fuels (
Exempted from s20 of the Clean Air Act 1993
)
RoI:
Wood logs, smokeless fuels or peat briquettes, but not petroleum coke
(Control of Atmospheric Pollution Regulations, 1970)
1