TRNT.BODYA
100000457 180118-40
Installer information
Trenton Co-Axial Venting Chart
Note: The vent must not exceed
a total length of 30 feet. Any
combination of rise and run may
be used but must be constrained
to the boundaries of this chart. A
Maximum of three (3) 90° elbows
may be used. Only one (1) 90°
elbow or combination of other
elbows equaling 90° can be used
without reducing horizontal run.
For each additional 90° elbow, or
an equal combination of elbows,
reduce horizontal vent run by 2
feet. Ensure vent pipe is properly
supported.
Damper Note:
The damper position is factory
set to the closed position. Every
venting configuration is different,
and the damper setting may need
slight adjustment.
(See page 33 for damper
adjustment).
No venting options
No venting options
Venting envelope
Venting envelope
1’
2’
3’
4’
5’
6’
7’
8’
9’
10’
11’
12’
13’
14’
15’
16’
17’
18’
19’
20’
21’
22’
23’
24’
25’
26’
27’
28’
29’
30’
31’
1’
2’
3’
4’
5’
6’
7’
8’
9’ 10’
11’ 12’ 13’ 14’ 15’
Note: For horizontal termination at the
end of venting which is no higher than 2
feet vertically, the Snorkel terminal must
be used. Otherwise, the regular terminal
can be used.
16’
Figure 25: Trenton venting chart examples.