35
TRNT.BODYA
100000457 180118-40
Installer information
Note: To test the gas pressure, turn off the gas supply to the gas stove before loosening test
point screws. Verify gas pressures with the gas stove lit and at the highest setting.
1. Remove back panel and locate the valve as seen in Figure 71.
2. Locate the inlet and outlet test points on the valve Figure 72. After locating test ports loosen the screws
within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and verify gas pressure with the gas stove lit and on its highest setting.
5. After testing is finished turn off gas supply, remove the pressure gauges and re-tighten the screws in the
test points.
The pilot flame level can be
adjusted by turning the adjustment
screw, using a flat-tip screwdriver,
as seen on the valve in Figure 72.
Gas Pressure Testing Procedure
Figure 70: Trenton pilot
assembly.
Figure 71: Control valve
location.
Pilot Flame Adjustment
Figure 72: Gas
control
valve.
Pilot flame level
adjustment screw
Pressure modulator
device
Main gas
solenoid
Pilot
solenoid
Inlet pressure
test point
Manifold pressure test
point