18
100000457 180118-40
TRNT.BODYA
Installer information
Co-Linear Venting
Intake
Air
Exhaust
Air
Co-Linear Venting Notes:
•
TN24 requires a 3 inch
diameter exhaust vent
and a 3 inch intake vent.
•
Max. Vent Height 35’
(15.25M) to termination
•
Min. Vent Height 10’
(3m) to termination.
High wind cap
Prairie cap
1. Measure chimney height, cut fl ex liner (min.10’
to termination) as required. Mark one pipe at
both ends to identify combustion air intake
pipe from fl ue outlet pipe.
2. Attach marked fl ex liner pipe to the intake side
of vent terminal. Seal and secure with sealant
and screws provided. Attach the other pipe
to the outlet side of vent terminal. Seal and
secure with sealant and screws provided.
3. Insert both fl ex liners from top of the chimney,
down through the damper opening.
4. Before attaching vent terminal to top of
chimney, apply a bead of caulking to top of
clay liner. Slip vent terminal over liner and
secure in place with lateral retaining bolts.
5. For larger chimneys, fl ashing will need to be
constructed according to local building codes.
Simpson Duravent High-Wind (cap style) Co-Linear
Kit w/Flex (46DVA-CL33) or Simpson Duravent Prairie
(cap style) Co-Linear Kit w/Flex (46DVA-CL33P) are
recommended for use with this appliance.
Visit http://www.duravent.com for kit details.
NOTE:
If venting the TN24 through an existing
fi replace opening using a co-axial to
co-linear adapter, the customer will have a
couple of aesthetic options which include:
1. Sealing up the existing fi replace opening
with a cover or other material, leaving
room in the cover or other material to
accommodate the adapter so that it is
positioned fl ush Figure 26 with the cover
or other material.
2. Positioning the TN24 so that it and
the adapter are located outside of the
existing fi replace opening.
Figure 26: Trenton co-linear venting confi guration.