Figure 127: SIT pilot assembly.
Maintenance
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for
unit to cool before servicing appliance. It is recommended that the fireplace and
its venting should be inspected at least once a year by a qualified service person.
Glass Door:
Warning: Do not operate fireplace with glass door removed, cracked or broken.
Replacement of the glass door should be done by a licensed or qualified service person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If
the glass becomes cracked or broken it must be replaced before using the fireplace.
Replacement door can be obtained from your nearest Pacific Energy Fireplaces dealer. The
size required is dependent on which version of Tofino is installed. Use original Tofino door
only. Do not substitute with any other type.
To remove broken glass, remove door frame as noted in See “Door Installation/Removal”
on page 15.
Install the new door onto the fireplace.
Annual Inspection:
a) Remove glass door and inspect if soot buildup is present. Inspect the burner
assembly and the ceramic glass baffle for soot buildup. If excessive
buildup of soot is present, have a qualified service person inspect and
adjust unit for proper combustion. Clean logs and burner with a brush
or vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper flame size and operation. Clean pilot
free of soot, dust or any other deposits (Figure 127 and Figure 128).
Have a qualified service person adjust the pilot flame.
c) Check that the vent pipe and vent terminal are open and free from
blockage or debris. If the venting is disassembled for cleaning, it
must be properly assembled and re-sealed. See Venting section in
Installation manual proper procedure.
d) Check glass panel gasket, replace the door if necessary.
It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable
vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace. Do not clean glass when hot.
PILOT FLAME
FLAME SENSOR
ELECTRODE
PILOT
Pilot
Igniter
Thermo-couple
Figure 128: Maxitrol pilot.
49
100000328
041119-56
i20 TOFINO
Содержание TOFINO i20 Maxitrol G6R
Страница 54: ...54 041119 56 100000328 i20 TOFINO...
Страница 55: ...55 100000328 041119 56 i20 TOFINO...