![Pacific energy TOFINO i20 Maxitrol G6R Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/pacific-energy/tofino-i20-maxitrol-g6r/tofino-i20-maxitrol-g6r_installation-instructions-manual_746208023.webp)
Gas Pressure Testing Procedure
Note: This section covers gas pressure testing for both SIT and Maxitrol gas valves.
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point
screws. Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove surround.
ports loosen the cap ends within the ports using a 3/16” Allan key.
3. If necessary, attach brass test extensions to the test ports. Extensions are not included (Figure 44).
4. Attach one end of hoses to brass extensions and the other end to the pressure gauge.
5. Turn gas supply back on and test pressures.
6. After testing is finished turn off gas supply, remove the pressure gauges, apply thread sealant to cap ends
Gas valve
Gas pressure
test ports
Figure 42: Gas valve location.
Pressure
out
Pressure
in
Figure 43: Gas pressure test ports.
Figure 44:
Installer supplied
gas valve test
port extensions.
Figure 45: Testing port caps with thread
sealant.
23
100000328
041119-56