background image

WARNING:  If the information in these  

instructions is not followed exactly a fire 

or explosion may result causing property  
damage, personal injury or death.  

INSTALLER:  
Leave this manual with the appliance.  
CONSUMER:  
Retain this manual for future reference.

This appliance is suitable for installation in a  

bedroom or bed sitting room.   

This appliance may be installed in an  after-

market permanently located,  manufactured 
home (USA only) or mobile  home, where not 
prohibited by local codes. 

 

This appliance is only for use with the type of  

gas indicated on the rating plate. This  appliance 

is not convertible for use with  other gases 
unless a certified kit is used.  

FOR YOUR SAFETY  

Do not store or use gasoline or other  flammable 
vapours and liquids in the vicinity  of this or any 
other appliance.  

WHAT TO DO IF YOU SMELL GAS  
 

•  Do not try to light any appliance.  
•  Do not touch any electrical Switch.  
•  Do not use any phone in your building.  
•  Immediately call your gas supplier from a 

neighbour’s phone. Follow the gas supplier’s 
instructions.  

•  If you cannot reach your gas supplier call the 

fire department.  

Installation and service must be performed  by 
a qualified installer, service agency or the  gas 
supplier.  

                  TOFINO

TOFINO  

INSTALLATION 
INSTRUCTIONS 

  

MODEL: TOFINO i20 
     (SIT & Maxitrol G6R versions)  
 
SERIES: A  
 
DIRECT VENT GAS INSERT

   

Visit www.pacificenergy.net for the most recent version of this manual

100000328-50

041119-56

INSTALLATION INSTRUCTIONS

Содержание TOFINO i20 Maxitrol G6R

Страница 1: ...ther gases unless a certified kit is used FOR YOUR SAFETY Donotstoreorusegasolineorother flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not...

Страница 2: ...ration 20 SIT controller 20 SIT gas valve 20 Gas valve for Maxitrol Configuration 21 Maxitrol controller 21 Maxitrol gas valve 21 Gas Pressure Check Output Efficiency 22 Gas Pressure Testing Procedure...

Страница 3: ...the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CL...

Страница 4: ...psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pres...

Страница 5: ...ed for servicing the unit must be replaced prior to operating Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by...

Страница 6: ...nsion and or contraction noises during the start up or cool down cycle Similar noises are found with your furnace heat exchanger or cook stove oven Warnings and Cautions WARNING Fire Hazard Can cause...

Страница 7: ...14 3 4 D 17 3 8 Use dimension C E 30 1 4 30 1 4 F 18 18 G 13 1 4 13 1 2 H 19 3 8 19 3 8 I 21 21 J 28 1 2 28 1 2 K 3 3 L 13 5 8 13 5 8 M 18 5 8 18 5 8 Fireplace Dimensions E I J F G H C D B A K L M Fig...

Страница 8: ...ofino Insert Backing Plate Dimensions Tofino i20 B A Figure 2 Tofino Surround dimensions HEIGHT WIDTH A B REGULAR 26 38 OVERSIZED 28 42 4 SIDED FULL FRAME 27 1 8 35 1 4 8 041119 56 100000328 i20 TOFIN...

Страница 9: ...nting the fireplace flue dampener may be blocked open or removed Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace before installing the insert Also smok...

Страница 10: ...ibles Refer to Figure 5 18 from center of fireplace to nearest combustible or to backing plate whichever is furthest Side wall Side wall Figure 5 Horizontal clearance to combustibles Horizontal Cleara...

Страница 11: ...adjustments along with the bubble sight Figure 7 to level the Tofino fireplace Adjustable Leveling Bolts Side to side levelling adjustments Rear to front levelling adjustment Bubble sight Figure 6 Le...

Страница 12: ...ure chimney height cut flex liner min 10 as required Mark one pipe at both ends to identify combustion air intake pipe from flue outlet pipe 2 Attach marked flex liner pipe to the intake side of vent...

Страница 13: ...installation of the Tofino the installer may want to remove the flue adapter and attach it to the flex tubes which will have previously been inserted down the chimney The installer must make sure that...

Страница 14: ...unit takes 2 AAA batteries The SIT Proflame controller Figure 14 is used along with the SIT Proflame gas valve See Figure 39 on page 20 The use of the SIT Proflame controller requires a remote contro...

Страница 15: ...and set aside Installation 1 Place the door over the opening of the fireplace 2 There are two hooks on the top of the handles and two hooks on the bottom of the handle and so the door must be placed s...

Страница 16: ...uding from the ceiling do not damage the panels Figure 22 Baffle and panel bracket Push tab against panel Figure 23 Perforated panel tab Side panel support tabs Baffle support tabs Figure 24 Baffle an...

Страница 17: ...g Be careful that the top corner of the panel closest to the front of the fireplace makes as little contact with the opening edge of the firebox Figure 27 as possible as this may damage the panel 3 Th...

Страница 18: ...e door removed place one end of the baffle over one of the two upper corners so that the baffle is resting on a rear peg and a front support Figure 31 2 Raise the opposite end of the baffle so that it...

Страница 19: ...dance with all building codes This section is intended as a guide for qualified technicians installing this appliance Consult local and or national building codes before proceeding Gas supply line con...

Страница 20: ...ch is located on the left hand side of the fireplace for easy access Remove the surround to gain access to the controller SIT gas valve The SIT gas valve assembly is mounted onto a caddy which is loca...

Страница 21: ...the surround to gain access to the controller Maxitrol gas valve The Maxitrol gas valve assembly is mounted onto a caddy which is located on the right hand side of the fireplace for easy access Remov...

Страница 22: ...requirements Input Pressure Natural Gas Propane Minimum 5 0 WC 12 5 WC Maximum 13 9 WC 13 9 WC Manifold Pressure High 3 8 WC 10 WC Low 1 7 WC 2 7 WC Tofino i20 SIT Version Gas Orifice Input NG Front A...

Страница 23: ...rts using a 3 16 Allan key 3 If necessary attach brass test extensions to the test ports Extensions are not included Figure 44 4 Attach one end of hoses to brass extensions and the other end to the pr...

Страница 24: ...e closed partially to reduce the speed of the intake air and thus calm the flames to a more natural look Over closure of this damper could cause an insufficient air supply to the fire which would resu...

Страница 25: ...Tofino venturi adjustments Venturi closed Figure 49 Venturi closed Venturi opened Figure 50 Venturi opened Note The venturi settings on the Tofino i20 units come preset from the manufacturer Units tha...

Страница 26: ...a thin layer of crushed glass on top of the burners and the burner tray Figure 54 When placing the crushed glass on the burner tray leave enough room around the pilot and rectifier flame so that it is...

Страница 27: ...ce Center base piece Figure 55 Log set base pieces Figure 56 Log number 1 Figure 57 Log number 2 Figure 58 Log number 3 Figure 59 Log number 4 Figure 60 Log number 5 Figure 61 Log number 6 Figure 62 E...

Страница 28: ...This gap is required for air flow Also secure the Ember pieces Retainer Figure 64 along the back of the rear burner This will help to keep the ember pieces from spilling over from the burner and down...

Страница 29: ...ing edge of the front burner as shown in Figure 70 and secure with supplied screws Figure 67 Right side mesh guard Figure 68 Right side mesh guard in place Figure 69 Front mesh guard Figure 70 Front m...

Страница 30: ...e 73 The base pieces in addition to adding an aesthetic dimension to the overall appearance help to complete an enclosure for holding the ember pieces glowing ember material pieces on top of the burne...

Страница 31: ...and rear burner trays Figure 78 Place extra ember pieces on the thin but noticeable gaps between the front base piece and the two side base pieces Figure 79 Keep the ember pieces from interfering with...

Страница 32: ...ld be very close to or just touching the center base piece 12 There is a location post on top of the 3rd log Figure 82 that is used to accommodate a slot located on the bottom of the 4th log Figure 59...

Страница 33: ...ass will be 14 Place the 6th log Figure 61 so that the top end rests on top of the 2nd log and the bottom end rests against the left wall panel and left base piece Figure 85 The bottom end should be c...

Страница 34: ...mber pieces Retainer Figure 86 along the back of the rear burner This will help to keep the ember pieces from spilling over from the burner and down into the air gap 2 Use 2 screws to secure the front...

Страница 35: ...e firebox as shown in Figure 91 35 100000328 041119 56 i20 TOFINO Figure 89 Front mesh guard in place Figure 90 Side mesh guard Front mesh guard Side mesh guard Figure 91 Front and side mesh guards in...

Страница 36: ...at the front and side pieces are touching each other Figure 94 These pieces will form containments for the ember material 5 Straddle the two 2nd log supports between the rear of the front burner and t...

Страница 37: ...ber material to cover the bottom of the burner trays Figure 96 7 Locate the Driftwood log set Figure 97 and install as follows 37 100000328 041119 56 i20 TOFINO Figure 96 Ember pieces in burner tray 5...

Страница 38: ...s on top of the rear edge of the center base piece Its long branch should cover the seam where the center base piece and right hand base piece meet The right hand tip of the log should just touch the...

Страница 39: ...ure 102 13 Finish log set installation by placing the 6th log so that one end lays on the left base piece and the other end lays on top of the 3rd log piece 39 100000328 041119 56 i20 TOFINO Figure 10...

Страница 40: ...106 All that is needed is to install the switch itself to the surround backing plate To install ON OFF Switch 1 Check that the ON OFF Switch cable is plugged into the SIT module jack X8 as shown in F...

Страница 41: ...ng plate positioned in front of the fireplace position the switch in behind the open slot in the backing plate and screw into place Figure 107 3 Install the surround backing plate and surround Figure...

Страница 42: ...k that the ON OFF Switch cable is plugged into the Maxitrol module as shown in Figure 109 Figure 108 Pre installed ON OFF switch assembly Figure 109 Switch connector at control module 2 Position the O...

Страница 43: ...plate ON OFF Flame UP Down Figure 112 On Off switch location for Maxitrol units 3 Use a 2mm Allen key to fasten the switch to the backing plate 4 Install the surround backing plate and surround Figure...

Страница 44: ...rative front and backing plate removed Figure 119 and Figure 120 press the button marked PRG on the caddy and press the program button once Figure 115 The module will beep 3 times indicating that it i...

Страница 45: ...t button is located here Figure 118 4 Press and hold the receiver s reset button Figure 118 until you hear two 2 beeps After the second longer beep release the reset button Within the subsequent 20 se...

Страница 46: ...by inserting its four hooks into the four slots on the fireplace frame Figure 121 3 Install the Standard front by inserting its four hooks into the corresponding slots on the backing plate Figure 122...

Страница 47: ...e of the Artisan Front as indicated in Figure 124 3 Mount the Artisan Front and the trim piece onto the backing plate as shown in Figure 125 Artisan Front Trim for Artisan Front Backing Plate Figure 1...

Страница 48: ...st be allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off switch to the fireplace Off 5 Allow sufficient length of time minimum 5 minutes for any gas in...

Страница 49: ...soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean logs and burner with a brush or vacuum cleaner paying close at...

Страница 50: ...tion Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing LAMP COMFORT FAN PILOT BURNER ON OF...

Страница 51: ...re Cable Thermocurrent Cable SW Thermocurrent Cable TC ON OFF Flame UP DOWN Antenna RESET Button Receiver Ignition Cable Main Burner Pilot Burner Figure 129 Maxitrol wiring diagram Wiring Diagram for...

Страница 52: ...wall 18 Hearth in front of appliance 0 Under appliance 0 Objects in front of appliance 36 WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damag...

Страница 53: ...Rating label location Figure 130 Rating label location The rating label for the Tofino is located on the left hand outside wall of the insert 53 100000328 041119 56 i20 TOFINO...

Страница 54: ...54 041119 56 100000328 i20 TOFINO...

Страница 55: ...55 100000328 041119 56 i20 TOFINO...

Страница 56: ...LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pa...