NEO 2.5 INSERT LE_221119-28

3

100003382

 Rating Label 

EPA Certified Emissions

2.0 grams per hour

LHV Tested Efficiency 1

78%

HHV Tested Efficiency 2

72%

EPA BTU Output 3

15,845 to 59.861 BTU/hr.

Maximum Wood Length

18 inches

Ideal Wood Length 

17 inches

Fuel

Seasoned Cord wood

Efficiency and BTU Output

1 Weighted Average Lower Heating Value (LHV) efficiency as 
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is 
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency 
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required 
to vaporize the water in the fuel
 3 The range of BTU outputs is based on efficiency using 
CSA B415 Performance testing of solid-fuel-burning heating 
appliances and burn rates from the low and high EPA tests 
using Douglas Fir dimensional lumber.

Experience will give you the right settings for proper combustion and efficient burning. Remember the correct 
air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather 
conditions.  With practice, you will become proficient in operating your heater and will obtain the performance 
for which it was designed.

This heater meets the 2020 U.S. Environmental Protection Agency's Cordwood emission limits for 
wood heaters sold after May 15, 2020 using ASTM 3053. Under specific test conditions this heater has 
been shown to deliver heat at rates ranging from 15,850 to 59,850 Btu/hr.

•  INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE 

PACIFIC ENERGY. 

•  CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE, 

CONCERNANT LES CODES, RESTRICTIONS ET EXIGENCES D’INSPECTION D’INSTALLATION 

DE VOTRE RÉGION. 

•  INSTALLEZ ET UTILISEZ SEULEMENT DANS UN FOYER PRÉFABRIQUÉ OU EN 

MAÇONNERIE. NE RACCORDEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE 

DESSERVANT UN AUTRE APPAREIL. 

•  COMPOSANTS REQUIS POUR L’INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE 

CONFORME À CAN/ULC-S635 OU CAN/ULC-S640. 

•  ALIMENTATION ÉLECTRIQUE : 115 V, 60 HZ, 1.2 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE 

DE L’APPAREIL. DANGER : RISQUE D’ÉLECTROCUTION.  

•  POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. AUCUN PORTE-BÛCHES NI FEU 

SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS DIRECTEMENT SUR L’ÂTRE. REMPLACEZ LA 

VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. 

•  INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - EN CERTAINES CONDITIONS, 

DES DÉPÔTS DE CRÉOSOTE PEUVENT SE FORMER RAPIDEMENT. 

•  UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. 

OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. CE POÊLE EST CONÇU UNIQUEMENT 

POUR BRÛLER DU BOIS DE CORDE. BRÛLER D’AUTRES MATÉRIAUX PEUT ENDOMMAGER 

LE POÊLE OU LE BÂTIMENT.

•  COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT

     TOUT TRAVAIL D’ENTRETIEN SUR L’APPAREIL.

•  INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND 

 OPERATING  INSTRUCTIONS. 

•  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND 

 INSTALLATION INSPECTION IN YOUR AREA. 

•  INSTALL AND USE ONLY IN MASONRY OR  FACTORY BUILT FIREPLACE. 

•  DO NOT  CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

•  COMPONENTS REQUIRED FOR  INSTALLATION : FULL FLUE LINER  CONFORMING TO CAN/

ULC-S635 OR CAN/ULC-S640. IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT 

FLUE  CONNECTION ASSEMBLY.

•  ELECTRICAL RATING 115V, 60HZ, 1.2 AMP. ROUTE POWER CORD AWAY FROM UNIT. 

•  DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

•  FOR USE WITH SOLID FUEL (CORDWOOD) ONLY.

  BURNING OTHER MATERIALS MAY CAUSE 

DAMAGE TO STOVE OR HOME.

•  DO NOT USE A GRATE OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH. 

•  OPERATE ONLY WITH FEED DOOR CLOSED.  OPEN TO FEED FIRE ONLY.  

REPLACE GLASS 

ONLY WITH CERAMIC GLASS. 

•  INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE, 

CREOSOTE BUILDUP MAY OCCUR RAPIDLY. 

•  THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. 

•  CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. 

•  IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER 

INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL 

LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE

CERTIFIED FOR USE IN CANADA AND U.S.A.

CERTIFIED TO / CERTIFIÉ POUR:ULCS628-93(R2016) / UL1482 (2011)

          

CLEARANCE TO COMBUSTIBLES

ADJACENT SIDE W

ALL

  C# 4001507

221019 

    NEO 2.5 INSERT LE 

100003739

Refer to Intertek’s Directory of Building Products for detailed information

MODEL / MODÈLE:

 

NEO 2.5 INSERT LE   

MADE IN CANADA

MANUFACTURED BY:

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

2975 ALLENBY RD., DUNCAN, BC  V9L 6V8

DATE OF MANUFACTURE

2.0 

g/hr

U.S. ENVIRONMENTAL PROTECTION AGENCY. 

Certified to comply with 2020 Cordwood particulate 

emission standards, Tested to ASTM E3053

MINIMUM CLEARANCE TO COMBUSTIBLES / DÉGAGEMENT MINIMUM AUX COMBUSTIBLES 

D

C

A

B

F

E

F

MEASURED FROM SIDE OF DOOR/ MESURÉ DU COTE DE LA PORTE
 

A)  ADJACENT SIDEWALL / PAROI LATÉRALE ADJACENTE  

 

380 MM / 15 In

 

B) SIDE FACING / REVÊTEMENT LATÉRAL MANTEL / MANTEAU  

295 MM / 11 1/2 In

MEASURED FROM INSERT SURROUND BROW 
 

C)  TOP FACING / REVÊTEMENT SUPÉRIEUR 

   405 MM / 16 In

 

D) MANTEL 

 

   405 MM / 16 In

E)  EMBER PROTECTION - FIRING SIDE / EPREUVE DU FEU, CANADA  

457 MM / 18 In

 

                                               FIRING SIDE, U.S.A.  

   405 MM / 16 In 

F)  EMBER PROTECTION - SIDES / AUTRES CÔTÉS. 

   200 MM /   8 In

 

INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH UNDER THE UNIT, EXTENDING A DISTANCE OF 16IN 

/ 406MM IN FRONT OF THE FIREPLACE OPENING FACE. TYPE 1 FLOOR PROTECTION APPROVED TO 

UL1618, MINIMUM 20GA STEEL MUST BE USED ADJACENT TO THE HEARTH//  INSTALLER UNIQUEMENT 

SUR UN COEUR NON COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm 

DEVANT LE FACE D’OUVERTURE DU FOYER. 

Содержание NEO 2.5 INSERT

Страница 1: ...ur safety follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in you area IMPORTANT THESE INSTRUCTIONS ARE TO REMA...

Страница 2: ...llow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in you area Please read this entire manual before you install an...

Страница 3: ...LE PO LE OU LE B TIMENT COUPEZ L ALIMENTATION LECTRIQUE AVANT TOUT TRAVAIL D ENTRETIEN SUR L APPAREIL INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY S INSTALLATION AND OPERATING INSTRUCTIONS C...

Страница 4: ...ads two or three logs at a time or 1 4 to 1 2 of fuel load and leaving the air inlet relatively wide open especially during the first 10 to 30 minutes after each loading when most of the smoke generat...

Страница 5: ...important that you have a clearly understood plan on how to handle a chimney fire 4 After the chimney fire is out the chimney must be cleaned and checked for stress and cracks before starting another...

Страница 6: ...Wet or green wood Coal charcoal Garbage Solvents Lawn clippings yard waste Unseasoned wood Railroad ties Manure or animal remains Materials containing rubber including tires Materials containing plast...

Страница 7: ...l and error and should be noted for future burns 2 To refuel adjust air control to high and give the fire time to brighten Open the door slowly this will prevent back puffing 3 Use wood of different s...

Страница 8: ...ate draft may cause back puffing into the room and plugging of the chimney Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft Remember the correct ai...

Страница 9: ...r otherwise impact glass When closing door make sure that no logs protrude to impact the glass If the glass gets cracked or broken it must be replaced before using the stove Replacement glass can be o...

Страница 10: ...ing the Chimney System Top Baffle Board Blanket Baffle Top Heat Shield and mounting bolts Baffle Gasket Brick Rail Tabs and Brick Rails Air Riser Tube in the back of the firebox Blower The optional bl...

Страница 11: ...r baffle DO NOT OPERATE WITH BAFFLE ASSEMBLY TUBES OR INSULATION REMOVED Baffle Removal 1 Remove retaining pin at the back of the firebox just under the baffle 2 Lift the Baffle up to disconnect from...

Страница 12: ...TOP Figure 1 NEO 2 5 Insert LE Dimensions The hearth must be raised 2 51mm above an adjacent combustible floor and must extend 16 406mm in front and 8 203mm beyond each side of the fireplace opening...

Страница 13: ...EO 2 5 Insert LE Minimum ember protection dimensions Ember protection Combustible floor in front of the fireplace insert must be protected from hot embers by non combustible material extending 16 406m...

Страница 14: ...DISTANCE MEASURED FROM TOP OF SURROUND BROW SIDE FACING AND ADJACENT WALL MEASURED FROM EDGE OF DOOR Mantel or Top Facing Hearth 11 1 2 292mm 8 203mm 16 406mm 16 406mm Clearances Figure 4 NEO 2 5 Inse...

Страница 15: ...Masonry Fireplace Inspect your fireplace for cracks loose mortar or other physical defects If repairs are required they should be completed before installing your insert The fireplace chimney must be...

Страница 16: ...for Lining Systems for New Masonry Chimneys 1 Measure the chimney height from the top of the existing flue to the floor of the hearth This will allow extra length of liner for flashing and rain cap 2...

Страница 17: ...en in use for some time Before installing clean your chimney system thoroughly 2 A full stainless steel rigid or flexible flue liner meeting type HT requirements 2100 F per 1777 U S or ULC S635 Canada...

Страница 18: ...in contact with the fireplace facing 3 Attach the Front Trim by inserting the mounting hooks into the slots between the fan mount brackets and the firebox on both sides of the firebox and sliding it...

Страница 19: ...blowers Suggested settings Combustion air control setting of Low all the way to the right operate blowers speed control on Low Combustion air control greater than Low operate blowers speed control at...

Страница 20: ...ing Plate Mounting Bracket by removing the two screws securing the bracket to the side casing of the unit 3 With a 3 8 10mm wrench loosen the two bolts securing the blower mounting bracket to the unit...

Страница 21: ...the slot in the right side end of the control assembly Figure 13 3 Remove the two screws securing the backing plate with the strain relief in it and rotate 180 degrees See Figure 14 You will lose appr...

Страница 22: ...ertically and push them back so that they make contact with the A bricks on the rear wall Then place a C brick on top of an A brick Figure 17 Figure 16 Left side rear wall A and B brick placement Figu...

Страница 23: ...at steps 2 and 3 for the opposite side wall 5 At rear of the firebox floor place an A brick in each corner and insert one B brick in between them as shown in Figure 19 6 Place two A bricks in front of...

Страница 24: ...ded Glass is Dirty 1 See 1 2 and 3 above 2 Door Gasket leakage Replace gasket Check door latch Low Heat Output 1 Wood may be wet Check wood and use drier wood if required 2 Fire too small Build a larg...

Страница 25: ...2 Baffle Tube 10 pack 80000365 18 Baffle 80000247 19 Heat Shield 80002441 20 Handle Removable Flue Collar 80000254 21 Flue Collar Gasket 80001983 22 Flue Collar Removable c w hardware 80000665 23 Doo...

Страница 26: ...INSERT LE_221119 28 26 100003382 48 1 22m 32 810mm 28 1 2 725mm 40 1 016m 11120004 Backing Plate STD 11120005 Backing Plate Oversized 11250011 Front Trim Met Black 11250012 Front Trim Stainless Steel...

Страница 27: ...NEO 2 5 INSERT LE_221119 28 27 100003382...

Страница 28: ...84 Web site http www pacificenergy net 2975 Allenby Rd Duncan B C V9L 6V8 2019 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission i...

Отзывы: