NEO 2.5 INSERT LE_221119-28
17
100003382
Direct Flue Connection - (USA only)
1. Measure from the first chimney flue liner to the top
of the Insert. Allow extra length of liner to insert into
flue tile.
2. Feed the stainless steel liner through the damper
area and into the first chimney flue tile. Seal around
pipe.
3. Push the Insert into position inside the fireplace and
attach the NEO Insert removable flue collar to the
liner. Use the rear adjusting legs to level the Insert.
Note: It is necessary to get access to the removable
collar through the flue outlet of the Insert, the baffle
should be removed (See “Baffle Removal” on page
11).
Into a Factory Built Fireplace
Your Insert may be installed into a factory built fireplace (size permitting) with the following requirements:
1. Inspect your fireplace for damage or other physical defects. The fireplace must be in good working
condition. If in doubt about its condition, seek professional advice. Check for creosote build up or other
obstructions inside the chimney, especially if it has not been in use for some time. Before installing, clean
your chimney system thoroughly.
2. A full stainless steel rigid or flexible flue liner meeting type HT requirements (2100°F) per 1777 (U.S.) or
ULC S635 (Canada) must be used for both safety and performance. The liner must be securely attached
to the Insert flue collar and the chimney top.
3. The surround must be sealed to the fireplace front or the damper area around the chimney liner must be
sealed to prevent room air entering the chimney cavity of the fireplace.
4. The air flow within and around the fireplace must not be altered by the installation of the Insert (i.e. no
blockage of louvers or cooling air inlet or outlet ports). This includes the circulating air chambers in a steel
fireplace or metal heat circulator.
5. Alteration of the fireplace in any manner is not permitted with the following exceptions:
a: external trim pieces which do not affect the operation of the fireplace may be removed and stored
on or within the fireplace for re-assembly if the Insert is removed.
b: the chimney damper may be removed to install the liner.
Chimney
Flue Liner
6" Stainless Steel
Rigid or Flex Liner
Mantel or
Top Facing
Direct Flue Connection
Figure 6: Neo 2.5 Insert LE Direct flue connection.