Electrical Supply
Circulating air blower electrical rating: 115V, 60 Hz. 1AMP
For your protection against shock hazard, use only a properly grounded outlet that will accept a three
pronged plug. Do not cut or remove the grounding prong.
Consult local codes or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code
and in the USA with the National Electrical Code, ANSI/NFPA 70 (latest edition).
Blower Replacement
1. Remove the Front Trim and Backing Plate. Set them aside carefully to avoid damage.
2. Remove the Backing Plate Mounting Bracket by removing the two screws securing the bracket to the side
casing of the unit.
3. With a 3/8”(10mm) wrench, loosen the two bolts securing the blower mounting bracket to the unit
(Figure 10).
Blower securing
scews
Figure 11: Blower mounting screws.
Mounting bracket
bolts
Figure 10: Blower mounting bracket bolts.
4. Disconnect the two wires leading to the blower motor.
5. Pull the blower mounting bracket bottom out first and then lift the blower up and back to remove from the
bolts.If replacing the right side blower, then disconnect the two wires leading to the thermo-switch at this
time as well.
6. Remove the three screws securing the blower to the mounting bracket and replace the blower (Figure 11).
7. Reverse all previous steps to reinstall the new blower.