NEO 2.5 INSERT LE_221119-28
19
100003382
Blowers
The Insert comes equipped with variable speed circulating air blowers. The blower system is thermostatically
controlled for automatic operation, as well manually with a convenient bypass switch.
Blowers Operation
• Automatic:
To operate the blowers automatically, push the rocker switch to the “O” or AUTO position
and set the fan speed control to a desired setting. This will allow the blowers to turn on automatically
once the Insert has come up to operating temperature. It will also shut the blowers off after the fire has
gone out and the appliance cooled to below a useful heat output range. On and Off times will vary with
installation and location of appliance.
• Manual:
To manually operate the blowers, push the rocker switch to the “l” or MANUAL position and set
the fan speed control to a desired setting. This will bypass the temperature switch and allow full control of
the blowers.
Suggested settings:
• Combustion air control setting of “Low”(all the way to the right), operate blowers speed control on “Low”.
• Combustion air control greater than “Low”, operate blowers speed control at desired setting.
Combustion Air
Consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the
Insert in one of two ways:
1. Outside air supply: Remove the cover from ash clean out in the existing fireplace. Place a rodent screen
in place of the cover. Install the Insert as described in the “Installation” section, making sure not to cover
the opening of the air inlet. When the installation is complete, seal the back surround to fireplace. This will
ensure combustion air is drawn from outside the house and under the unit.
2. Room air supply: The insert can get combustion air from the front under the firebox but it must have
adequate air for combustion provided in the room the unit is installed in. This may involve providing make
up air from outside the house.
L2 (black)
G (green)
L1 (white)
Speed
Control
Blowers
Thermo
Switch
By-pass
Rocker Switch
Figure 9: Blower electrical drawing.
Содержание NEO 2.5 INSERT