The minimum required clearances to surrounding combustible materials when installed into a masonry or
factory built fireplace are listed below and (See Figure 2 on page 12)
37
1/2
”
953mm
15”
381mm
Adjacent
Wall
MINIMUM 68” FROM BASE OF
UNIT TO CEILING
MANTEL DISTANCE
MEASURED FROM TOP OF
SURROUND BROW
SIDE FACING AND ADJACENT
WALL MEASURED FROM
EDGE OF DOOR
Mantel or Top Facing
Hearth
11
1/2
”
292mm
8”
203mm
16”
406mm
16”(406mm)
Clearances
Figure 4: NEO 2.5 Insert LE Clearances.
Minimum Clearances to Combustibles
Side of Door to Adjacent Sidewall..................................... 15 in.(380 mm)
Side of Door to Side Mantel Pillar................................ 11 1/2 in.(290 mm)
The top of Surround brow to the Mantel.............................16 in.(405 mm)
The top of Surround brow to the Top Facing......................16 in.(405 mm)
Bottom of unit to Ceiling.......................................................68 in.(1.7m)