Installation Instructions

Listed Certified for USA. and Canada

Certified to: ANSI Z21.44a-1992, Can1-2.19-M81, CGA I.R.#41, CGA I.R.#55, CAN/CGA 2.17-1991

Model Number ZDV1001

Stock #’s: ZDV 360, 960, 1160, 1560, 1960, 2560

“Zero Clearance”

Direct Vent Gas Fireplace

Read this complete manual before beginning installation.

These instructions must be kept with the unit for future reference.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

What To Do If You Smell Gas

Do not try to light any appliance.

Extinguish any open flame.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone.

If you can not reach your gas supplier, call the fire department.

KINGSMAN INDUSTRIES

A Division of R-Co. Inc.

3 Winfield Way

Winnipeg, Manitoba, Canada R2R 1V8

Phone (204)-632-1962

Warning: 

Improper installation, alteration, service or maintenance can cause property damage, personal

injury or losses of life. Refer to this manual. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.

Printed in Canada 05/96 Part # 1000-P920CP Revision 2

Summary of Contents for "Zero Clearance" ZDV1001

Page 1: ...nce What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier...

Page 2: ...8 Vent termination 9 10 Venting graph 10 General vent installation information 11 Installation of top flue side wall venting 11 12 Installation of back vents 13 Repair parts list 13 Valve System Part...

Page 3: ...vice person A professional service person should be called to inspect this appliance annually Make it a practice to have all your gas appliances checked annually 6 Control compartments burners and air...

Page 4: ...llation recommendation when installing this fire place against non insulated exterior wall or chase it is recommend ed that the outer walls be insulated to conform to applicable insula tion codes Dryw...

Page 5: ...pressure testing of the gas supply piping sys tem at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved fl...

Page 6: ...should any solid fuels wood paper card board coal be used in this appliance Note It is normal for your gas fireplace to give off some odor the first time it is burned This is due to the curing of the...

Page 7: ...plug on the inside wall of the access area opposite the fan Large holes are provided to allow wiring to enter the access area on the left of the unit Connect the power sensor and variable speed wall...

Page 8: ...that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the wall switch is in the ON position NOTE The On Off wall switch...

Page 9: ...driveway located on public property 7 feet 2 1m minimum 3 V NOTE Clearances are to the terminal center line Add 6 inches to clearances not indicated as measured from center line NOTE Local Codes or R...

Page 10: ...s are required the horizontal run length must be reduced to 7 feet How To Use The Vent Table 1 Determine the height of the system and the number of bends required 2 Having determined the vertical dist...

Page 11: ...ing on the wall Cut a hole through the exterior wall allowing for a 11 x 11 minimum inside framing or an 8 1 2 diameter hole if venting through a non combustible wall Center wall thimble over 11 x 11...

Page 12: ...NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plum...

Page 13: ...d must be cut to comply Install wall thimble Place fireplace into place and secure to floor with nailing tabs Step 5 Mount vent termination make sure 4 and 7 pipes are siliconed Caulk around wall thim...

Page 14: ...urround Kits ZISAB Surround Antique Brass ZISPB Surround Polish Brass ZISAL Surround Almond ZISBG Surround Burgundy ZISGR Surround Green ZISSAB Surround Slim Line Antique Brass ZISSPB Surround Slim Li...

Page 15: ...h ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating Check generator with millivolt meter...

Page 16: ...ing its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the...

Reviews: