SRM Setup Mode |
Copyright © P Squared Ltd 2013
2.
First you need to put the SRM in Setup Mode. To do that hold MONITOR AUTO PREFADE
and PRESENTER AUTO PREFADE and GUEST AUTO PREFADE buttons and press the
MONITOR PGM button 5 times within 2 seconds.
A single meter sweep indicates entry into setup mode and the buttons can be released.
Selecting The Settings Page You Want To Work With
As outlined above, the settings are divided into separate ‘pages’ with common settings clustered on
appropriate pages. This allows is to alter many settings without using dozens of button
combinations.
Once you are in Setup Mode (see above), the current settings ‘page’ is displayed on the LED Meter
such that the number of the scale that the lights reach is the ‘page’ currently selected.