SRM Operations Manual
25
Setting Up The Myriad Intelligent Interface (MII) |
Copyright © P Squared Ltd 2013
The indicator remains on screen at all times but only ‘lights up’ when a ‘mic’ fader on the SRM is
opened.
Setting Up The Myriad Intelligent Interface
Setting up the SRM to interact with Myriad via the MII Is very simple, the steps below will guide you
through the whole process.
Please note that installation process outlined using a Windows 7 Professional PC but MII has also
been tested on Windows XP Pro computers. You will also need to be running Myriad v3.6.1 or higher
to use MII.
1.
Plug a standard USB A to B cable in to the back of the SRM mixer (see below) and plug the
other end into your Myriad playout PC.
2.
Plug in and power on the SRM.
3.
Your Myriad playout PC should recognise a new USB hardware device and install support
software automatically. Please note that there is no driver that needs to be installed. After a
few minutes, you should see a popup message (bottom right hand corner of the start bar)
confirming that the hardware has been installed correctly.
The SRM installs as USB Serial Converter. It is recommended that you check that it has
installed correctly by looking in Device Manager.