OMRM 113 User Manual
111 |
P a g e
protection
4
IF output
function
number
error 1
protection
Undefined numbers are used
for the function assignment of
the output signals (SO1, SO2,
and SO3).
Correct the function assignment to
the connector pins.
6
CL fitting error
protection
The deviation counter clear
function is assigned to an input
signal other than SI7.
Correct the function assignment to
the connector pins.
7
INH fitting
error
protection
The command pulse inhibition
input enable function is
assigned to an input signal
other than SI10.
Correct the function assignment to
the connector pins.