background image

                                                                                                                                                                                                                                                   Filename:CONTROL CENTER MANUAL 

                                                                                       

 

 12/11/06 

Page 2 of 10

 

CAUTION  

RISK OF ELECTRIC SHOCK 

 

DO NOT OPEN  

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK 

DO NOT REMOVE COVER (OR BACK) 

NO USER-SERVICEABLE PARTS INSIDE 

REFER SERVICING TO QUALIFIED PERSONNEL 

 

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 
to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of 
sufficient magnitude to constitute a risk of electric shock to persons. 

 

 

The exclamation point within an equilateral triangle is intended to alert the user of the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying the 
appliance. 

 

 
 

The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as 
vases, shall be placed on the apparatus. 

 
 
 

IMPORTANT SAFETY INSTRUCTIONS 

 

1.

 

Read these instructions - All the safety and operation instructions should be read before this OWI product is 
operated. 

2.

 

Keep these instructions - The safety and operating instructions should be kept for future reference. 

3.

 

Heed all warnings - All warnings on this product and in these operating instructions should be followed. 

4.

 

Follow all instructions - All operating and other instructions should be followed. 

5.

 

Do not use this apparatus near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a 
wet basement, near a swimming pool, swamp or salivating St. Bernard dog, etc. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. - This OWI 
product should be situated so that its location or position does not interfere with its proper ventilation. For 
example, the Component should not be situated on a bed, sofa, rug, or similar surface that may block any 
ventilation openings, or placed in a built-in installation such as a bookcase or cabinet that may impede the 
flow of air through ventilation openings. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including 
amplifiers) that produce heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider 
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.  

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 
the point where they exit the apparatus. 

11.

 

Only use attachment/accessories specified by the manufactures. 

12.

 

Use only with the cart, stand, tripod, bracket or table specified by the manufacturer, or sold 
with the apparatus. When a cart is used, use caution when moving the cart/apparatus 
combination to avoid injury from tip-over.  

 

Содержание CCRC-403

Страница 1: ...llation Instructions Model CCRC403 CCRC403RS232 CONTROL CENTER by OWI Established 1978 OWI Incorporated 17141 Kingsview Ave Carson CA 90746 USA Tel 310 515 1900 www owi inc com Technical Support 310 515 1900 ...

Страница 2: ...htub washbowl kitchen sink laundry tub in a wet basement near a swimming pool swamp or salivating St Bernard dog etc 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions This OWI product should be situated so that its location or position does not interfere with its proper ventilation For example the Component should not be ...

Страница 3: ...e induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a period of time The U S Government s Occupational Safety and Health Administration OSHA has specified the permissible noise level exposures shown in the following chart According to OSHA any exposure in excess of these permissible limits could result in some hearing loss To ensure agains...

Страница 4: ...arther away Before starting We recommend that the power supply be located above the ceiling in an electrical box with a cover It will fit into a 3 or 4 gang box The power supply is very special and should not be replaced with an off the shelf 12 volt supply This is a 15 volt supply and is designed to deliver full power when combined with the CCRC main board The power supply is UL rated and will op...

Страница 5: ...not connect the shield In this configuration there are two available inputs to be used for Line or Mic inputs for each room As the room is set up the back ground music can be adjusted appropriately Similarly two styles of music can be available on Ch s 2 and 3 leaving Ch 1 for the room input With the popularity of small audio mixers being used in hotel rooms any number of microphones can be used a...

Страница 6: ...PKR CH1 Red to Black to phoenix connectors SPKR CH 2 Red to Black to phoenix connectors These are both 25 watts each 4 Connect the UL listed 15 Volt transformer supplied to input the amplifier The wires must not be crossed and will damage the Control Center if this is done Please note that the power supply must be plugged in to a 110 volt outlet You may need to place the power supply into a 3 or 4...

Страница 7: ...load LED s Yes Input Level Controls Yes Type Digital Level Controls Output Amplifier Class D Power Level 25Watts 4 Ohm Maximum Power 50 Watts 2 Ohm With higher current power supply Frequency Range 50Hz to 20kHz Fidelity Excellent used by top Hi Fi Mfrs Applications Schools Hotel Motel meeting room combiner Restaurant Meeting rooms Conference facilities Output Power Control The unit is designed suc...

Страница 8: ...mplifier output to the speakers or the three volume settings Except for the J K L keys holding a key down A S D F G H smoothly moves the volume up or down When a letter is typed the CCRC403 sends back that same letter It is not necessary or desirable to press the enter key after a letter entry The last volume setting of a channel is stored in a special memory When the CCRC403 is turned off and the...

Страница 9: ...Filename CONTROL CENTER MANUAL 12 11 06 Page 9 of 10 ...

Страница 10: ... mailed to OWI Inc within 10 days following the date of purchase Units must be sent to OWI Inc or to the dealer where purchased 6 OWI INCORPORATED Date Purchased _____________________ 17141 Kingsview Ave Model Number _____________________ Carson CA 90746 Serial Number _____________________ Keep this part for your record CUT AND MAIL OWI INCORPORATED 17141 Kingsview Ave Carson CA 90746 LIMITED WARR...

Отзывы: