2-2
DLT LoaderXpress™
I
NSTALLATION
*MKYVI6IEV4ERIP'SRRIGXSVW8IVQMREXSVERH'EFPIW
4S[IV'EFPI
The AC power cable is a standard grounding AC cable which attaches to an IEC-
compatible connector on the rear panel. Connect the cable to the connector on the
module, and connect the other end to a reliably grounded AC outlet or rack power
outlet.
To maintain product safety compliance, use a power cord with a suitable electrical
rating that is approved for the country where the product is used. In the US, use a UL
listed cord; in Canada, a CSA certified cord; and in Europe, use a Harmonized cord
marked <HAR> or a nationally certified cord.
-RXIVJEGIW
The LXL4105 and LXL4110 are supplied with a single-ended Fast SCSI-2 interface,
and the LXL7110 with a single-ended Fast/Wide SCSI interface. The SCSI-2 interface
uses two female 50-pin Centronics-type connectors. SCSI-2 cables and terminators are
secured to the connectors by spring clips. The Fast/Wide SCSI interface uses high-
density 68-pin connectors. Fast/Wide SCSI cables and terminators are secured to the
connectors by jackscrews.
The drive and the robotics are separate SCSI devices. Each requires a unique SCSI
address, because they are daisy-chained on the same bus.
A terminator of the proper type (single-ended, not differential) must be installed at the
end of the bus, as explained below in the section headed Interface Cable and
Terminator Installation.
Содержание DLT LoaderXpress
Страница 4: ...ii DLT LoaderXpress...
Страница 14: ...xvi DLT LoaderXpress...
Страница 20: ...1 6 DLT LoaderXpress INTRODUCTION...
Страница 64: ...3 6 DLT LoaderXpress MAINTENANCE...
Страница 75: ...DLT LoaderXpress A 63...
Страница 76: ...A 64 DLT LoaderXpress...
Страница 78: ...B 2 DLT LoaderXpress...