6
Version 1.0
www.ovationlight.com
tor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last
fixture.
Power connection
Power Requirements
The Pioneer 100 zoom luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire
contains an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the power in socket in the next fix
-
ture till all are connected.
Caution:
maximum power linking - 8 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color
Connection
International
Brown
Live
L
Blue
Neutral
N
Yellow/green
Earth(Ground)
Operation
The Pioneer 100 zoom can operate different modes. In each mode you can run the fixture as a stand
alone fixture or in a master/slave confiugration. This next section will detail the differences in the operat
-
ing modes.
Control Menu Map
MENU
SUB MENU
OPERATION
Addr
d001-d512
RDM/DMX address
CHnL
2CH
Channel mode
3CH
4CH
5CH
Strb
S.01-s.20
Strobe with spead increasing
uL--
u.000-u.255
Dimmer
FL--
F
.
000-255
Zoom function
nodE
nod.0
Dimmer speed 0 (no delay)
nod.1
Dimmer speed 1
nod.2
Dimmer speed 2
nod.3
Dimmer speed 3
nod.4
Dimmer speed 4 (slowest speed)
Id
Id.01-Id.66
ID address setting
tEnP
-25~100
Fixture temperature
UErn
Firmware version
rSEt
yes/no
Reset
pnnF
(1.2~24.0)F
PWM refresh rate adjustment(KHz)