9
Version 1.0
www.ovationlight.com
CH5 is used to select the target ID address.
DMX value
Function
DMX value
Function
DMX
value
Function
000-009
ID1-ID66
212
ID23
235
ID46
010-019
ID1
213
ID24
236
ID47
020-029
ID2
214
ID25
237
ID48
030-039
ID3
215
ID26
238
ID49
040-049
ID4
216
ID27
239
ID50
050-059
ID5
217
ID28
240
ID51
060-069
ID6
218
ID29
241
ID52
070-079
ID7
219
ID30
242
ID53
080-089
ID8
220
ID31
243
ID54
090-099
ID9
221
ID32
244
ID55
100-109
ID10
222
ID33
245
ID56
110-119
ID11
223
ID34
246
ID57
120-129
ID12
224
ID35
247
ID58
130-139
ID13
225
ID36
248
ID59
140-149
ID14
226
ID37
249
ID60
150-159
ID15
227
ID38
250
ID61
160-169
ID16
228
ID39
251
ID62
170-179
ID17
229
ID40
252
ID63
180-189
ID18
230
ID41
253
ID64
190-199
ID19
231
ID42
254
ID65
200-209
ID20
232
ID43
255
ID66
210
ID21
233
ID44
211
ID22
234
ID45
Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should
be carried out periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend clean
-
ing on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture:
1.
Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2.
Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure
compressed air.
3. Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent
solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft,
clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tis
-
sue or cotton swab moistened with glass cleaner or distilled water.
4.
Check that the fixture is dry before reapplying power.
Fuse Replacement
This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel.
To replace a fuse:
1.
Disconnect the fixture from power and allow it to cool for at least 10 minutes.
2.
Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and
rating only.
3.
Reinstall the fuseholder cap before reapplying power.
Troubleshooting
Listed below are a few common problems that you may encounter, with solutions.