Caution!

Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric 
shock when touching the wires!

Avoid looking directly into the light source!
Wear protective glasses and other PPE (personal protective equipment) when working on or near 

the fixture.

For your own safety, please read this user manual carefully before you initial start-up.
Follow operating safety precautions and pay attention to warning signs methods and equipment 
on the user manual.

Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 

20 rating.
The ambient temperature must always be between -5° C and +45° C. 

Always make sure you are connecting this product to the proper voltage in accordance with the 

specifications in this manual or on the product’s specification label.Make sure it is grounded when 

using it!
Unplug mains lead before opening the housing!

Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture 

and the powercord from time to time.

Make sure to replace the fuse with another of the same type and rating.

Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot 
during operation. After use, wait for a cool-down period of at least 10 minutes before handling or 
transporting the device.

Every person involved with the installation, operation and maintenance of this device has to

- be qualified

- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet

Introduction

Thank you for having chosen Pioneer 100 zoom. You will see you acquired a powerful and versatile de-
vice.
Unpack your item. Before you initial start-up, please make sure that there is no damage caused by trans-
portation. Should there be any, consult your dealer and do not use the device.

Safety instructions

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to 
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warn-
ing notes written in this user manual. Always disconnect from the mains, when the device is not in use 
or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts 

inside the device. Maintenance and service operations are only to be carried out by authorized dealers.

Overview

Содержание Pioneer 100 ZOOM WW/CW

Страница 1: ...USER MANUAL PIONEER 100 ZOOM WW CW 100W LED fresnel with zoom ...

Страница 2: ...he fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Protocol 7 ID address selection 8 Fixture Cleaning 9 Fuse Replacement 9 Troubleshooting 10 The fixture does not work no light 10 Technical specifications 10 Table of contents ...

Страница 3: ...ts of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of t...

Страница 4: ... this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat surface that is oriented at any angle Ensure that the sur face and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the...

Страница 5: ...ough the eyebolt in the back of the fixture and around a secure anchoring point Do not loop the safety cable around the fixture s mounting bracket only as this will leave the fixture un secured if it separates from the bracket DMX 512 connection connection between fixtures Occupation of the XLR connection 1 Group 2 Signal 3 Signal DMX OUT 1 Group 2 Signal 3 Signal DMX IN If you are using controlle...

Страница 6: ...nnection cables as below Cable color Connection International Brown Live L Blue Neutral N Yellow green Earth Ground Operation The Pioneer 100 zoom can operate different modes In each mode you can run the fixture as a stand alone fixture or in a master slave confiugration This next section will detail the differences in the operat ing modes Control Menu Map MENU SUB MENU OPERATION Addr d001 d512 RD...

Страница 7: ... for example the ad dress in the 2 channel mode to channel 3 the device will use the channel 3 to 4 for control Universal DMX Control This function allows you to use a universal DMX 512 controller to control the dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs RDM control The Pioneer 100 zoom can communicate using RDM Remote Device Managemen...

Страница 8: ...r speed 3 206 255 Dimmer speed 4 slowest speed 5 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Zoom 000 255 zoom function CH4 Dimmer mode 000 005 Menu setting 006 055 Dimmer speed 0 no delay 056 105 Dimmer speed 1 106 155 Dimmer speed 2 156 205 Dimmer speed 3 206 255 Dimmer speed 4 slowest speed CH5 ID address setting 00...

Страница 9: ...tes I e smoke fog residue dust dew In heavy club use we recommend clean ing on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wip...

Страница 10: ...K optional Color Rendition CRI 97 R9 90 TLCI up to 98 Zoom scale 25 65 motorized Power connection PowerCON in out Maximum power linking 8 units Signal connection 3 pin XLR in out 5 pin optional DMX channels 2 3 4 5 Control mode RDM DMX Master slave Housing Colour black Aluminum Size barn door excluded 331 x 210 x 345 7mm 13 x 8 3 x 13 6in Package carton 448 x 338 x 400mm 17 6 x 13 3 x 15 7in N W 6...

Отзывы: