47
N_RESET
R
TYPE_FLOAT/4
Displays the number of times reset is executed.
48
PCT_INCL
R
TYPE_FLOAT/4
Indicates the percentage of total with "Good" status compared to
all total values measured.
49
GOOD_LIM
W
TYPE_FLOAT/4
Sets the threshold for PCT_INCL to determine OUT status is
"Good"
50
UNCERT_LIM
W
TYPE_FLOAT/4
Sets the threshold for PCT_INCL to determine OUT status is
"Uncertain"
51
OP_CMD_INT
W
TYPE_ENUM/1
A command to reset total (manual reset) by an operator
52
OUTAGE_LIM
W
TYPE_FLOAT/4
Maximum duration which functions of this block can be
maintained in the event of electricity outage.
53
RESET_CONFIRM.STATUS
W
TYPE_ENUM/1
If "Confirm Reset" is configured for INTEG_OPT, reset is not
executed until RESET_CONFIRM is set.
54
RESET_CONFIRM.VALUE
W
TYPE_ENUM/1
55
UPDATE_EVT.UNACKNOWLEDGED
W
TYPE_ENUM/1
Generates an alert when a change is made to static parameters
56
UPDATE_EVT.UPDATE_STATE
R
TYPE_ENUM/1
57
UPDATE_EVT.TIME_STAMP
R
TYPE_TIME/8
58
UPDATE_EVT.STATIC_REVISION
R
TYPE_U16/2
59
UPDATE_EVT.RELATIVE_INDEX
R
TYPE_U16/2
60
BLOCK_ALM.UNACKNOWLEDGED
R
TYPE_ENUM/1
Displays description of an alarm when a block alarm occurs
61
BLOCK_ALM.ALARM_STATE
R
TYPE_ENUM/1
62
BLOCK_ALM.TIME_STAMP
R
TYPE_TIME/8
63
BLOCK_ALM.SUB_CODE
R
TYPE_ENUM/2
64
BLOCK_ALM.VALUE
R
TYPE_U8/1
65
BLOCK_ERR_DESC_1
R
TYPE_ENUM/4
Information of BLOCK_ERR