•  External transmitters or signal conditioners can be eliminat-

ed  by direct connection of the sensor output to : 

  – DCA

   ID02 : 

DC mV 

±20mV, ±50mV, ±100mV, ±200mV 

w/24V Exc.

  – DCV 

   

ID01 : 

DC-Volts 

2V

/20V/200V

 w/24V Exc.

 

 

ID05 : 

DC-Volts 

2V

/20V/200V

 w/24V Exc. and Zero offset    

          adjustable pot

•  Optional isolated 14 bit analog output. User or factory scalable 

to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any desired  

digital span from ± one count to the full scale range of – 1999 

to 9999 (12000 counts).

•  Optional Isolated Modbus RTU RS-485 serial communication 

with selectable baud rate (9600, 19200), address and parity. 

•   Auto-sensing AC/DC power supply. For voltages between 
     

85-265 VAC / 95-300 VDC (PS1) 

or 15-48 VAC / 10-72 VDC (PS2).

•  Standard red or optional green or super bright red 4-digit LED 

with display range –1999 to 9999 (12000 counts).

•  Red or green 0.8” LED large display option
•  Four annunciator LEDs provide front panel alarm status  

indication for up to four setpoints.

•  Up to optional six relays in combination of six, four or two 4 

Amp Form A relays or two 9 Amp Form C with two or four 4 

Amp Form A relays are available.

•  Automatic intelligent averaging smooths noisy signals, while 

providing a fast display response to real input signal changes.

•  Three-button programming from the front panel  

(UP, DOWN and PROGRAM buttons).

Auto Calibration Mode . . . . . . . . . . . . 5

Auto Calibration Procedure . . . . . . . . 5

Case Dimensions . . . . . . . . . . . . . . . 13

Connector Pinouts . . . . . . . . . . . 10-11

Controls and Indicators . . . . . . . . . . . 2

Component Layout. . . . . . . . . . . . . . 12

Digital Span Selection for Analog

Range Output. . . . . . . . . . . . . . . . . . . 6

Decimal Point & Brightness Selection. . 6

General Features . . . . . . . . . . . . . . . . 1

Glossary of Programming Symbols . . 2

Input Module Component Glossary . . 13

Installation Guideline . . . . . . . . . . . . 11

Lens Cover & Metal Surround Case 14

Manual Rescaling. . . . . . . . . . . . . . . . 4

Manual Rescaling Procedure. . . . . . . 4

Meter Assembly . . . . . . . . . . . . . . . . 10

Modbus RTU & RS-485 Settings . . . . 7

Modbus RTU Implementation  . . . . . . 7

Modbus Address for DL-40 Registers 8

Ordering Information  . . . . . . . . . . . . 15

Setpoint & Relay Configuration Mode . . . .9

Software Features  . . . . . . . . . . . . . . . 1

Software Logic Tree . . . . . . . . . . . . . . 3

Specifications. . . . . . . . . . . . . . . . . . . 1

Two Point Analog Output Range 

Setting and Calibration. . . . . . . . . . . . 6

General Features

Specifications

Software Features

Index

LEOPARD FAMILY

DL-40JANUS-DCA

20/50/100/200mV DC Full Scale

DL-40JANUS-DCV

2/20/200V DC Meter

Two scaling methods - MANUAL (no external sig-

nal source required) and AUTO (requied an exter-

nal signal source). Optional Modbus RS-485 serial, 

analog and up to six relays output. 

•  Front panel selectable four-level brightness control for digital 

display and setpoint LEDs.

•  Four programmable setpoints.
•  Relay activation can be selected to occur above (HI) or below 

(LO) each setpoint.

•  Hysteresis setting for all four setpoints.  Delay on make and 

delay on break for SP1 and SP2.

•  Peak and Valley.  View and Reset.
•  Program Lock switch

4 Digit 0.56” or 0.8” LEDs

in a 1/8 DIN CASE

Input Specs: ..............Depends on Input signal conditioner 

A/D Converter: ..........14 bit single slope

Accuracy: ..................±(0.05% of r 2 counts)

Temp. Coeff.: .............100 ppm/°C (Typical)

Warm up time: ...........2 minutes

Conversion Rate: ......5 conversions per second (Typical)

Display: ......................4 digit 0.56" Red LED display (std)

0.56” Green, 0.8" Red/Green, or  

0.56" Super Bright Red are optional. 

Range 0 to 9999 counts. 

Polarity: .....................Assumed positive. Displays – negative

Decimal Selection: ....Front panel button selectable, X•X•X•X•

Positive Overrange: ..Top segments of digital display flash

Negative Overrange: .Bottom segments of digital display flash

Relay Output: ............Up to Six Relays in combination of six, 

four or two 4 Amp Form A relays or two 

9 Amp Form C with two or four 4 Amp 

Form A relays. 

Analog Output: .........Isolated 16 bit user scalable mA or V

  AIC (mA out) ...........4-20 mA @ 0 to 500Ω max loop resistance

  AIV (volts out) .......... 0-10 V DC @ 500 Ω or higher resistance

Power Supply: ...........AC/DC Auto sensing wide range supply

  PS1 (std) ................85-265 VAC / 95-300 VDC, 50-400Hz @ 3W

 PS2 .........................15-48 VAC / 10-72 VDC, 50-400Hz @ 2.5W 

Operating Temp.: ......0 to 50 °C

Storage Temp: ...........–20 °C to 70 °C.  

Relative Humidity: ....95% (non condensing)

Case Dimensions: ....1/8 DIN, Bezel: 96x48 mm (3.78”x1.89”) 

Depth behind bezel: 117 mm  (4.61”) 

Plus 11.8 mm (0.47”)  for Right-angled 

connectors, or plus 20 mm (0.79”) for 

Straight-thru connector.

Weight: .......................6.5 oz., 8.5 oz when packed

Certification ...............UL Listed.

DC Amp or DC Volt Meter, Transmitter and Controller

Summary of Contents for DL-40JANUS-DCA

Page 1: ... Features 1 Software Logic Tree 3 Specifications 1 Two Point Analog Output Range Setting and Calibration 6 General Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS DCA 20 50 100 200mV DC Full Scale DL 40JANUS DCV 2 20 200V DC Meter Two scaling methods MANUAL no external sig nal source required and AUTO requied an exter nal signal source Optional Modbus RS 485 serial analog...

Page 2: ...ted by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the or buttons A dotted box indicates these functions are omitted or bypassed when the related hard ware is not present To explain software programming procedures logic diagrams are used to visually assis...

Page 3: ...IMAL POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal Point dp Display Brightness br TWO POINT ANALOG OUTPUT CALIBRATION SEE PAGE 6 MANUAL RESCALING MODE See Page 4 SELECTION FOR ANALOG RANGE OUTPUT See Page 6 confirm SP4 confirm confirm confirm This men...

Page 4: ... out STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL to inPt 2 Press the P button Display toggles between oFSt and the previous offset setting STEP C Set the Offset on the Digital Display 1 Using the and buttons adj...

Page 5: ...Two Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL to inPt input calibration 2 Press the P button Display toggles between ZErO and the previous zero setting STEP C Set the Meter s Low Input Signal Reading on the Digital Display 1 Apply a zero or l...

Page 6: ...Press the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to the desired decimal point setting 2 Press the P button Display toggles between br and the previous br setting STEP F Set the Display Brightness 1 Using the and buttons adjust the display to the desir...

Page 7: ... counts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal location then combine the two Display counts are in Two s Complement notation a Hex values for 0 to 9999 are 0x0000 to 0x270F b Hex values for 1 to 1999 are 0xFFFF to 0xF831 c Over range is indicated by a...

Page 8: ...9 HYST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRES4 Setpoint 4 setting 40022 0x0015 UINT16 R W 0 9999 HYST4 Setpoint 4 Hysteresis setting 40023 0x0016 UINT16 R W 0 3 RLYMOD Relay activation polarity H L disabled e g HHHH 40024 0x0017 UINT16 R W 0 4...

Page 9: ...he SP2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the desired hysteresis HYSt value 2 Press the P button Display toggles between SP3 and the previous SP4 setting STEP J Set Setpoint 3 SP3 No doM or dob 1 Using the and buttons adjust the display to the de...

Page 10: ...ng with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 265 V AC 95 370 V DC PS1 or 18 48 V AC 10 72 V DC PS2 Pin 14 AC DC Neutral Neutral power supply line Pin 15 AC DC line Live power supply line Analog and RS 485 Output Board Pins Pins 16 and 17 Analog ...

Page 11: ...ood air circulation 3 Separate input output leads from power lines to protect the meter from external noise Input output leads should be routed as far away as possible from contactors control relays transformers and other noisy components Shielding cables for input output leads is recommended with shield connection to earth ground near the meter preferred 4 A circuit breaker or disconnect switch i...

Page 12: ...Span Pot ID05 ID01 Zero Offset Pot Zero Offset Pot Input Range Header Input Range Header ID01 DC Volts 2 20 200V Custom w 24V DC Exc Custom 200V 20V 2V ON OFF 24V Exc 24V Exc Decrease Span Increase SPAN DC VOLTS PIN 1 PIN 2 PIN 3 Custom 200V 20V 2V ON OFF 24V Exc 24V Exc Decrease Span Increase SPAN ZERO DC VOLTS PIN 1 PIN 2 PIN 3 ID05 DC Volts 2 20 200 Custom V DC with Offset and 24V Exc 0 _ Offse...

Page 13: ...o be offset 5 of full scale 100 to 100 counts Input Module Component Glossary 96 mm 3 78 48 mm 1 89 3 9 mm 0 15 typical FRONT VIEW 1 8 DIN 96x48mm These dimensions are increased by 1 6mm 0 06 when the metal surround case is installed The 96x48mm case is particularly suitable for mounting in mosaic panels or insulative panels up to 2 thick They can also stack mount 2 up in existing cutouts for 1 4 ...

Page 14: ...c case is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference EMI The metal case slides over the polycarbonate case and is held firmly in place by spring type non return clips The Metal Surround Case must be factory installed on the polycarbonate case and once...

Page 15: ...NPUT MODULES ANALOG OUTPUT RELAY OUTPUT OPTIONS ACCESSORIES OA____ DL 40JANUS DCA Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different special options and or accessories that you may require to be included with this product Please see our website www texmate com to configure a meter and see current pricing Ordering ...