L--740--28--E
1
14. PRODUCT CODE EXPLANATION
14.1 Type U
●
Main code (CA00A to CA080)
○ :
Compatible,
× : Not
applicable,
△
:
Request inquiries
① ②
Model
Selector Chart
C A ALTImass Type U
CA00A, CA001
CA00
3
CA00
6
CA0
10
CA015
CA0
25
CA040, CA050
CA080
High temp. service:
CA0
25, CA040, CA050
High temp. service:
CA0
80
Low temp. explosionproof service:
CA
025, CA040, CA050, CA080
③ ④ ⑤
Meter size/Nominal Diameter
JIS Flange ASME·JPI Flange DIN Flange
Ferrule
Screw
0 0 A
R1/4
0 0 1
R1/4
0 0 3
10mm
1/2˝
DN 15
10A
Rc3/8
0 0 6
10mm
1/2˝
DN 15
10A
Rc3/8
0 1 0
15mm
1/2˝
DN 15
15A
Rc3/8
0 1 5
15mm
1/2˝
DN 15
15A
Rc3/4
25mm
1˝
DN 25
0 2 5
25mm
1˝
DN 25
25 (ISO), IDF 1S
40mm
1˝·1/2˝
DN 40
0 4 0
40mm
1˝·1/2˝
DN 40
38 (ISO), IDF 1.5S
0 5 0
50mm
2˝
DN 50
51 (ISO), IDF 2S
0 8 0
80mm
3˝
DN 80
76.1 (ISO), IDF 3S
100mm
4˝
DN 100
⑥ —
⑦
Fluid category
L Liquid
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
G Gas
○ ○ ○ ○ ○ ○ ○ ○ × × ○
⑧
Temp. category ※1
2
Standard (200℃ and lower)
○ ○ ○ ○ ○ ○ ○ ○ × × ×
3
High temp. (350℃ and lower)
× × × × × × × × ○ ○ ×
4
Low temp. explosionproof (−200℃ to +50℃)
× × × × × × × × × × ○
⑨
Major parts material
S SUS316L
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
M Alloy C
× ○ ○ ○ ○ ○ ○ ○ × ○ ○
H
Alloy C ※2
× ○ ○ ○ ○ ○ ○ ○ × ○ ○
P
Alloy C (High Pressure) ※3
× × × ○ ○ × × × × × ×
⑩ ⑪
Process connection
J 1
JIS10K
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
J 2
JIS20K
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
J 3
JIS30K
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
J 4
JIS40K
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
J 6
JIS63K
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
A 1
ASME150
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
A 3
ASME300
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
A 6
ASME600
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
P 1
JPI150
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
P 3
JPI300
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
P 6
JPI600
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
D 1
DIN PN10 ※4
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
D B
DIN PN16 ※4
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
D 3
DIN PN25 ※4
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
D 4
DIN PN40 ※4
(Standard nominal size ※9)
× ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
K 1
JIS10K
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
K 2
JIS20K
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
K 3
JIS30K
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
B 1
ASME150
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
B 3
ASME300
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
B 6
ASME600
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
Q 1
JPI150
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
Q 3
JPI300
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
Q 6
JPI600
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
E 1
DIN PN10 ※4
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
E B
DIN PN16 ※4
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
E 3
DIN PN25 ※4
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
E 4
DIN PN40 ※4
(Expanded nominal size ※10, ※11)
× × × × △ △ × ○ × × ×
T T Screw (Male)
○ × × × × × × × × × ×
T C Screw (Female)
× ○ ○ ○ ○ × × × × × ×
H S ISO Ferrule
× ○ ○ ○ ○ ○ ○ ○ × × ×
Z 9 Special
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
※1: Explosionproof specifications are restricted depending on the temp. class.
※2: When "H" is chosen for "Major parts material
⑨
", CA003 are always threaded connection,
and CA006 to CA080 are loose flange type.
※3: When "P" for high pressure is chosen as "Major parts material
⑨
", threaded connection is always applied.
※4: DIN flange is applied only when "S" and "M" are chosen for "Major parts material
⑨
".
※5: "2, 3" for "Communication protocol
" are not applicable.
※6: CRN is applicable only to CSA explosionproof and ASME flange models.
※7: When selecting "B" for "Regulations
⑮
" following limitations apply:
Code
③④⑤
are only to size 040, 050 and 080.
Code
⑨
is only to S.
Code
⑩⑪
are only to A1, A3, A6, D1, DB, D3 and D4.
※8: The maximum measurement temperature of integral type is 150℃.
"High temp. and low temp. type CA00A to CA003" are only "(transmitter) separate type".
⑫ —
⑬
Explosionproof
0 Non-explosionproof
1 TIIS
2 ATEX, IECEx
3 KCs
4 CSA (C-US)
5 EAC
7
NEPSI ※5
T ITRI
⑭
Ex-proof temp. class
0 Non-explosionproof
1 T1
2 T2
3 T3
4 T4
5 T5
⑮
Regulations
0 Standard
G High Pressure Gas Safety Act
(Approved product)
w/Material test certificate
H High Pressure Gas Safety Act
(Individual test)
w/Material test certificate
J High Pressure Gas Safety Act
(Completion inspection)
w/Material test certificate
M Gas Business Act
w/Material test certificate
T Fire Service Act
w/Material test certificate
S
Ship Classification Society Pattern Approval
Separately mounted only
P
Ship Classification Society Pattern Ap w/Material test certificate
Separately mounted only
C
CRN (Canadian Registration Number) Pattern approval ※6
K CRN (Canadian Registration Number) Pattern approval
+ w/Material test certificate ※6
F
w/Material test certificate
B
PED ※7
⑯ —
⑰
Transmitter
1 ALTImass
⑱
Transmitter construction ※8
1 Integrally mounted
2 Separately mounted
⑲
Power source
1 20 to 30VDC
2 85 to 264VAC (safety rating: 100 to 240VAC) 50/60Hz
⑳
Pulse
0 When "2, 3" are chosen for "Communication interface
"
B Voltage
G Open drain (open collector output equivalent) (Standard)
Communication protocol
1 HART communication (HART protocol version 7, Bell202)
2 FOUNDATION Fieldbus H1 communication (ITK version6)
3
PROFIBUS PA communication (Profile version3.02)
4 Modbus communication (RS-485 Modbus protocol)
Version code
A Version code: A (CA003 only)
B Version code: B
—
Special shape designation
0 Standard
Z Special shape (including polishing, long neck)
※9
: The standard nominal size of each model is as follows.
Model
JIS Flange
ASME•JPI Flange
DIN Flange
CA003
10mm
1/2″
DIN15
CA006
10mm
1/2″
DIN15
CA010
15mm
1/2″
DIN15
CA015
15mm
1/2″
DIN15
CA025
25mm
1″
DIN25
CA040
40mm
1·1/2″
DIN40
CA050
50mm
2″
DIN50
CA080
80mm
3″
DIN80
※
10: The expanded nominal size of each model is as follows.
Model
JIS Flange
ASME•JPI Flange
DIN Flange
CA015 (Request inquiries)
25mm
1″
DIN25
CA025 (Request inquiries)
40mm
1·1/2″
DIN40
CA080
100mm
4″
DIN100
※
11: Expanded nominal size is applied only when "S" and "M" are chosen for
"Major parts material
⑨
".
⑧
⑦
−
⑤
④
③
②
①
−
⑮
⑭
⑬
−
⑪
⑩
⑨
⑰
㉒
㉑
⑳
⑲
⑱
Model
Process connection
Temp. category
Fluid category
Meter size/Nominal Diameter
Major parts material
Power source
Transmitter construction
Version code
Special shape designation
Communication protocol
Pulse
Transmitter
Regulations
Explosionproof
Ex-proof temp. class
Main code
/ / / Additional code
− ㉔