L--740--28--E
11
Item
Description
Model
CS010
CS015
CS025
CS040
CS050
CS080
Nominal flange size
15mm or 1/2" 15mm or 1/2"
25mm or 1"
40mm or 1
・
1/2"
50mm or 2"
80mm or 3"
Materials
Wetted parts
SUS316L
Housing
SUS304
Process connection
JIS 10, 20K RF / ASME (JPI) 150 RF, IDF ferrule
Acceptable fluid
Liquid
Density range
0.5 to 1.0g/mL, 0.7 to 1.3g/mL, 1.0 to 1.5g/mL (
※
1)
Measurable temperature range
-
40 to
+
130
℃
for both integrally and separately mounted types (
※
2)
Heatproof temperature
150
℃
max. (
※
3)
Max. operating pressure
Varies according to process connection.
Sensor housing withstands
2.8MPa
Flow direction
Forward / Reverse
Explosionproof configuration
Refer to section 10.4
Dusttight, waterproof configuration
IP66 / 67
3.1.2 Type S sensor unit general specifications
※
1: Density range varies with the fluid used.
※
2: Refer to section 10.4 for explosionproof specification.
In case of non-explosionproof type, the maximum measurement temperature is 130
℃
. However, the product
must be used within the maximum ambient temperature of 45
℃
.
※
3: CIP/SIP procedures must be performed within the heatproof temperature range.
※
: Temperature class for integral type is T4.
※
: For products that are compliant with the High Pressure Gas Safety Act, consult OVAL.
3.1.3 Type B sensor unit general specifications
Item
Description
Model
CB006
CB010
CB015
CB025
CB040
CB050
Nominal flange size
10mm
or 1/2"
15mm
or 1/2"
15mm
or 1/2"
25mm
or 1"
40mm
or 1
・
1/2"
50mm
or 2"
Materials
Wetted parts
SUS316L
Housing
SUS304
Process connection
JIS 10, 20, 30K / ASME (JPI) 150, 300, 600 RF, IDF ferrule
Acceptable fluid
Liquid
Density range
0.3 to 2.0g/mL
Measurable temperature range
-
40 to
+
125
°
C (
※
1)
Heatproof temperature
150
℃
max. (
※
2)
Max. operating pressure
Varies according to process connection.
Flow direction
Forward / Reverse
Explosionproof configuration
Refer to section 10.4
Dusttight, waterproof configuration
IP66 / 67
NOTE
※
1:
Refer to section 10.4 for explosionproof specification.
In case of non-explosionproof model, up to 125
℃
is permitted. However, the product must be used within
the maximum ambient temperature of 45
℃
.
※
2: CIP/SIP procedures must be performed within the heatproof temperature range.
NOTE
※
1: Loose flange is applied. Ferrule connections of models CS010 and CS015 comply with ISO2852.
※
2: Density range varies with the fluid used.
※
3:
Refer to section 10.4 for explosionproof specification.
In case of non-explosionproof models, the maximum measurement temperature of integrally mounted
type is 130
℃
. However, the product must be used within the maximum ambient temperature of 45
℃
.
※
4: CIP/SIP procedures must be performed within the heatproof temperature range.
※
: Temperature class for integral type is T4.
※
: If polished wetted parts are desired, contact OVAL.
●
Stainless steel tube type (CS010 to CS080)
Item
Description
Model
CS010
CS015
CS025
CS040
CS050
CSR50
Nominal flange size
10mm or 1/2" 15mm or 1/2"
25mm or 1"
40mm or 1
・
1/2"
50mm or 2"
80mm or 3"
Materials
Wetted parts
SB338 Grade-9
+
TB480H
Housing
SUS304
Process connection
JIS 10, 20K / ASME (JPI) 150 / IDF ferrule (
※
1)
Acceptable fluid
Liquid
Density range
0.5 to 1.0g/mL, 0.7 to 1.3g/mL, 1.0 to 1.5g/mL (
※
2)
Measurable temperature range
-
40 to
+
130
℃
(
※
3)
Heatproof temperature
150
℃
max. (
※
4)
Max. operating pressure
Varies according to process connection.
Sensor housing withstands
2.8MPa
Flow direction
Forward / Reverse
Explosionproof configuration
Refer to section 10.4
Dusttight, waterproof configuration
IP66 / 67
NOTE
●
Titanium tube type (CS010 to CSR50)