L--740--28--E
1
10.4.10 Electric wire connection part of integral type / separate type converters
■ TIIS, NEPSI explosionproof
Use attached cable gland. It is needed to use rubber packing which fits with the outer diameter of using
cable for the cable gland. The cable outer diameters fitting to attached rubber packings are as follows;
Packing ID
Cable OD
Remarks
φ
9
φ
8.1 to
φ
9.0
Used for the case of FISCO Explosion-proof
(Only 1 piece for output)
φ
10
φ
9.1 to
φ
10.0
φ
11
φ
10.1 to
φ
11.0
Standard Feature
(4 kinds at the left are attached.)
φ
12
φ
11.1 to
φ
12.0
φ
13
φ
12.1 to
φ
13.0
φ
14
φ
13.1 to
φ
14.0
Accessories for Converter Electric Wire Connection Part: 2 pieces, Standard Feature Type Cable Gland
Unit: mm
Ca
bl
e
G
la
nd
〈Caution〉
◆
Seal off properly not to make the infiltration of rain water and dust from cable, rubber packing, screw
tightening part and so on.
◆
The use of parts other than attached cable gland is prohibited.
◆
Do not install equipment while leaving the connection of blanking plug attached at shipping.
◆
Please refer to our service center if any parts are missing, damaged and so on.
◆
FISCO Explosionproof is not applicable in case of NEPSI Explosionproof
Integral Type Converter
Separate Type Converter
Screw Size: G3/4
Screw Size: G3/4