L--740--28--E
●
High pressure service models (CA010 and CA015)
Item
Description
Model
CA010 (high pressure service)
CA015 (high pressure service)
Materials
Wetted parts
Flow tube: Alloy C, Manifold: Equivalent to Alloy C (CX2MW)
Housing
SUS304
Process connection
Screw-in Rc 3/8
Screw-in Rc 3/4
Acceptable fluids
Liquid and gas
Density range
0.3 to 2.0g/mL
Viscosity range
Max.10000mPa
・
s (
※
1)
Temperature range
Separately mounted :
-
200 to
+
200
℃
, Integrally mounted:
-
200 to
+
150
℃
(
※
2) (
※
3)
Max. operating pressure
36MPa at room temperature
43MPa at room temperature
Sensor housing withstands (
※
3)
3.0MPa
2.2MPa
Flow direction
Forward / Reverse
Explosionproof configuration
Refer to section 10.4
Dusttight, waterproof configuration
IP66 / 67
●
Low temperature explosionproof service models (CA025 to CA250)
Item
Description
Model
CA025 CA040 CA050 CA080 CA100 CA150 CA15H CA200 CA20H CA250
Nominal flange size
25mm, 1",
DN25
40mm, 1
・
1/2",
DN40
50mm, 2",
DN50
80mm, 3",
DN80
100mm, 4",
DN100
150mm, 6", DN150
200mm, 8", DN200 250mm, 10",
DN250
Materials
Wetted parts
SUS316L, Alloy C,Alloy C
SUS316L
Housing
SUS304
Process connection (
※
1) JIS 10, 20, 30,40,63K RF / ASME (JPI) 150, 300, 600 RF
DIN PN 10, 16, 25, 40 RF (
※
2), IDF ferrule (
※
3)
JIS 10, 20, 30K RF / ASME (JPI) 150, 300, 600 RF
DIN PN 10, 16, 25, 40 RF (
※
2)
Acceptable fluids
Liquid and gas
Liquid
Density range
0.3 to 2.0g/mL
Viscosity range
Max.10000mPa
・
s
Temperature range
-
200 to
+
50
℃
(Separately mounted only) (
※
4)
Tube withstands
9.4MPa (at 20
℃
)
13.56MPa (at 20
℃
) 10.6MPa (at 40
℃
) 8.8MPa (at 40
℃
)
Max. operating pressure
Varies according to process connection. (
※
5)
Sensor housing
withstands (
※
6)
1.6MPa
1.8MPa
1.4MPa
—
Flow direction
Forward / Reverse
Explosionproof
configuration
Refer to section 10.4
Dusttight, waterproof
configuration
IP66 / 67
NOTES
※
1: When "SUS316L" or "S Alloy C" is selected for the materials of wetted parts, the flange material
is "SUS316". (CA025 to CA080)
※
2: For the material of DIN flange, you cannot select "Alloy C".
※
3: For application to foods, this product does not comply with CE marking.
※
4: Refer to section 10.5 for the ambient temperature.
※
5:
Refer to section 3.1.5 for PED specification.
※
6: This pressure does not represent the rated test pressure of a pressure vessel, but 1/4 of the breakdown test
pressure at OVAL (distorted enclosures do not constitute a failure of the test), or the data obtained from the
FEM analysis, whichever is lower (or safer).
※
: For the product compliant with High Pressure Gas Safety Act or CE marking, consult us.
※
: Only separately mounted transmitter is applicable.
NOTES
※
1: If the viscosity is 10000mPa·s or more, contact OVAL.
※
2: Refer to section 10.4 for explosionproof specification.
Refer to section 10.5 for the ambient temperature.
※
3: This pressure does not represent the rated test pressure of a pressure vessel, but 1/4 of the breakdown
test pressure at OVAL (distorted enclosures do not constitute a failure of the test), or the data obtained
from the FEM analysis, whichever is lower (or safer).
※
: For products that are compliant with the High Pressure Gas Safety Act, consult OVAL.