L--740--28--E
1
15.2 Type S product codes
Item
Product Code
Description
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱
Model
C S
ALTImass Type S
Nominal size
0 1 0
15mm connection (1/2") (
※
5)
0 1 5
15mm connection (1/2")
0 2 5
25mm connection (1")
0 4 0
40mm connection (1
・
1/2")
0 5 0
50mm connection (2")
R 5 0
80mm connection (3") Titanium Tube Type only
0 8 0
80mm connection (3") Stainless Steel Tube Type only
Fluid category
H
High density liquid (1.0 to1.5g/ml)
M
Ordinary density liquid (0.7 to 1.3g/ml)
L
Low density liquids (0.5 to 1.0g/ml)
Temp. category (
※
1)
1
Standard (below 130
°
C)
Pressure category
1
Standard
Major parts material (
※
9)
S
SUS316L (except for CSR50) Stainless Steel Tube Type only
T
SB338 Grade-9
+
TB480H (except for CS080) Titanium Tube Type only
Process connection
B
Ferrule
C
JIS 10K
D
JIS 20K
H
ASME 150
L
JPI 150
Z
Other than above
Transmitter construction (
※
2)
1
Integrally mounted
2
Separately mounted
Power source
1
20 to 30VDC
2
85 to 264VAC (Safety rated 100 to 240VAC), 50/60Hz
Analog output (
※
3, 4)
A
Output 1: Mass flow Output 2: Mass flow
B
Output 1: Mass flow Output 2: Density
(※
6
)
C
Output 1: Mass flow Output 2: Temperature
D
Output 1: Mass flow Output 2: Volume flow (true density)
(※
6
)
E
Output 1: Mass flow Output 2: Volume flow (fixed density)
F
Output 1: Density Output 2: Temperature
(※
6
)
G
Output 1: Volume flow (true density) Output 2: Density
(※
6
)
H
Output 1: Volume flow (fixed density) Output 2: Density
(※
6
)
J
Output 1: Volume flow (true density) Output 2: Temperature
(※
6
)
K
Output 1: Volume flow (fixed density) Output 2: Temperature
X
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Pulse output (
※
3, 4)
A
Output 1: Mass flow
Single pulse
B
Output 1: Volume flow (true density )
(※
6
)
C
Output 1: Volume flow (fixed density)
D
Output 1: Mass flow Output 2: Mass flow
Double pulse
E
Output 1: Mass flow Output 2: Volume flow (true dens.)
(※
6
)
F
Output 1: Mass flow Output 2: Volume flow (fixed density)
G
Output 1: Vol. flow (true dens.) Output 2: Vol. flow (true dens.)
(※
6
)
H
Output 1: Vol. flow (fixed dens.) Output 2: Vol. flow (fixed dens.)
J
Output 1: Volume flow (true dens.) Output 2: Mass flow
(※
6
)
K
Output 1: Volume flow (fixed density) Output 2: Mass flow
X
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Pulse output type (
※
3)
0
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
1
Open drain pulse (standard)
2
Voltage pulse
Communication interface
1
HART communication
Bell202
2
FOUNDATION fieldbus H1 communication (
※
3)
ITK version6
3
PROFIBUS PA communication (
※
3)
Profile version3.02
4
Modbus communication
RS-485 Modbus protocol
Explosionproof rating (
※
8)
0
Non-explosionproof
1
TIIS
2
ATEX, IECEx
3
KOSHA/KTL (
※
7)
4
CSA
5
GOST (
※
7)
7
NEPSI (
※
7)
Explosionproof temperature class
0
Non-explosionproof
3
Sensor unit: Temp. class T3, separate transmitter only
4
Sensor unit: Temp. class T4
NOTES
※
1
:
Explosionproof specification has restrictions on temperature class.
※
2
:
If temperature of the fluid exceeds 80
℃
, only "Separately mounted" type is available for the transmitter construction.
※
3
:
When FOUNDATION fieldbus, PROFIBUS is selected for communication interface,
product code categories of analog output is "X" and pulse output is "X" (pulse output type:"0").
※
4
:
When "Volume flow (fixed density)" is selected for analog output or pulse output, fixed density will be applied.
※
5
:
JIS connection is 10mm for the titanium tube type.
※
6
:
Available only for the titanium tube type.
※
7
:
Communication interfaces "FOUNDATION fieldbus H1 communication" and "PROFIBUS PA communication" are
unavailable. (in preparation)
※
8
:
Applicable explosionproof rating for CSR50 are TIIS, ATEX, and IECEx only.
※
9
:
If the major parts material
⑨
is "T", your existing transmitter may not be compatible. If you plan to use the existing
transmitter, contact OVAL.
The new product code has been implemented since April 2017.
Therefore, the product code explanation of the old product code will not be updated after April 2017.
Contact OVAL for any inquiries about the old product code.
※
: