Specifications
70
900-0145-01-01 Rev A
Definitions
The following is a list of initials, terms, and definitions used in conjunction with this product.
Table 17
Terms and Definitions
Term
Definition
12V AUX
Auxiliary connection that supplies 12 Vdc to control external devices
AC
Alternating Current; refers to voltage produced by the inverter, utility grid, or generator
AGS
Advanced Generator Start
DC
Direct Current; refers to voltage produced by the batteries or renewable source
DVM
Digital Voltmeter
GND
Ground; a permanent conductive connection to earth for safety reasons; also known as
Chassis Ground, Protective Earth, PE, Grounding Electrode Conductor, and GEC
Grid/Hybrid™
System technology which optimizes both grid-interactive and off-grid options
Grid-interactive,
grid-intertie, grid-tie
Utility grid power is available for use and the inverter is a model capable of returning
(selling) electricity back to the utility grid
HBX
High Battery Transfer; a function of the remote system display
IEC
International Electrotechnical Commission; an international standards organization
LBCO
Low Battery Cut-Out; set point at which the inverter shuts down due to low voltage
NEU
AC Neutral; also known as Common
Neutral-to-ground
bonding
A mechanical connection between the AC neutral (Common) bus and the ground (PE)
bus; this bond makes the AC neutral safe to handle
Off-grid
Utility grid power
is not
available for use
PV
Photovoltaic
RELAY AUX
Auxiliary connection that uses switch (relay) contacts to control external devices
RTS
Remote Temperature Sensor; accessory that measures battery temperature for charging
System display
Remote interface device (such as the MATE3), used for monitoring, programming and
communicating with the inverter; also called “remote system display”
Three-phase, 3-phase A type of utility electrical system with three “hot” lines, each 120° out of phase;
each carries the nominal line voltage with respect to neutral; each carries voltage with
respect to each other equaling the line voltage multiplied by 1.732
Utility grid
The electrical service and infrastructure supported by the electrical or utility company;
also called “mains”, “utility service”, or “grid”
Содержание GS3548E
Страница 1: ...Radian Series Inverter Charger GS7048E GS3548E Operator s Manual...
Страница 6: ...Table of Contents 4 900 0145 01 01 Rev A This page intentionally left blank...
Страница 64: ...Troubleshooting 62 900 0145 01 01 Rev A NOTES...
Страница 75: ...Index 900 0145 01 01 Rev A 73 V Vent Fan Control 44 W Warning Symbol 5 Warnings 58 Website 12 67...