䡵
Carry out functional check: Remove cover of the USB interface
➝
red LED must
briefly flash once a second.
䡵
Replace cover.
䡵
Align the pipe housing and place it onto the base plate. The pipe housing must
completely seat on the base plate (refer to the detail drawing in Fig. 20)!
OTT Pluvio
2
S with orifice rim heater: Ensure that the sockets in the connection
block are not contaminated.
Cover
Red LED
USB interface
Fig. 18: Carrying out the functional check.
Connector block including
sockets for the plug contacts
for the orifice rim heater
Abb. 19: Connection block for the plug
contacts for the orifice rim heater.